Installation Procedure:

Take a moment to view all drawings and read “special Installation note” on page 4 of this manual before proceeding with 

installation. Connect Faucet Autmator model FA400 exactly as shown in drawing, with sensor cable connection at left. 

Failure to install Faucet Automator Model FA400 exactly as shown will result in premature product failure and will void 

all warranties including extended warranty. Also, do not forget step 7.

1. Make sure surface area is clean and free of debris.
2.

 

**If using deck plate, place plate on deck immediately over center sink hole**.

Install new faucet by placing sensor wire through the riser and the hole in the sink that is designated for spout.
Make sure that wire is not pinched or cut during installation. 

Cutting or severely crimping sensor wire will cause faucet to 

malfunction and will also void warrantee

. Sensor wire is specifically designed to resist damage, simple careful

 

steps and 

common sense is all that is necessary for a complete and rewarding installation process. 

You may use silicon or similar sealer  

between faucet and deck plate.

3. Fasten Solid Brass Pipe Coupler to faucet shank using plumbers putty or Teflon tape.
4.

Affix Solid Brass Riser above plate (if used), then place faucet above Solid Brass Riser.

5. Slide rubber washer and stainless steel washer over faucet shank. Insert sensor wire through special “C” groove in washers.
6. Install retainer nut over faucet shank and tighten. (Do Not Over Tighten).
7. Remove stainless steel braided hose from package and fasten the small end of hose to threads located inside of shank.
8. Locate a spot on the wall that you feel is suitable for installing Faucet Automator FA400. The spot selected should be within 

reach of braided hose and sensor wire. Place Faucet Automator FA400 against the wall and mark the spots (2) where 
mounting holes will be. Using drill size ¼” drill 2 holes, insert supplied anchors in the holes. 

This step is for battery Powered Faucets Only. If your faucet is AC powered, skip this step.

9. Remove rubber band (or tape) that keeps the Faucet Automator’s cover to its base. Remove black square rubber cap off 

battery compartment, plug battery wire harness into battery pack. Make sure that harness plug makes solid contact with 
battery pack. Place black square rubber cap back onto battery compartment. Using 4 small screws fasten Faucet Automator 
cover to base.

10. Faucet Automator FA400 using supplied fasteners.
11. Install shank hose to Faucet Automator’s water outlet (top).
12. Align groove in sensor wire plug with pin in Faucet Automator FA400 sensor receptacle, insert plug into receptacle, fasten 

plug nut by hand only. 

DO NOT CROSS THREAD OR OVER TIGHTEN.

Before proceeding to steps 11 or 12, purge both hot and cold water lines for at least a minute each at high volume. Purging 
water lines clears out dirt and debris that would otherwise find its way to screen filter.

 ***For single water source application install 

cold water

 supply hose to Faucet Automator’s water inlet. 

Do not install hot 

water supply hose only in single water source application as this may result in scalding injury.

.

***For dual water temp system install mixing valve outlet to Faucet Automator’s water inlet.
Install hot and cold water supply hoses to mixing valve. Turn angle stops on. Check for leaks.
13. 

This step is for AC Powered Faucets Only. Battery powered faucets ignore this step. Plug Automator to wall AC.

To enable the faucet to activate from a farther distance or to stay on longer after hands are removed, see “sensor range 

adjustment” section of this manual.

To increase or decrease water flow volume, see “flow rate adjustment” section of this manual.

Operation:

Place hands under spout and directly in front of neck mounted sensor, water will begin to flow out in less than a second, water 
flow rate is governed by aerator and supply pressure, water temperature is governed by selection at angle stops, mixing valve, as 
well as water temperature in supply pipes

. Please remember, automatic faucets employ “presence” not 

“motion” sensors. An idle object placed directly underneath spout will immediately activate 
faucet.

Remove hands and water will cease to flow within 1-3 seconds.
If hands are left underneath spout for 30 or 60 seconds, water will automatically shut off. To initiate flow again move hands away 
from faucet and start at step 1.

When attempting to run water over small objects such as a tooth brush, it may be necessary 

to bring object closer to sensor to initiate water flow, when water begins to flow, move 
object back under stream of water. Once user “gets the feel” of the faucet this step may be 

skipped. 

 

1

Содержание FA400

Страница 1: ... battery pack Make sure that harness plug makes solid contact with battery pack Place black square rubber cap back onto battery compartment Using 4 small screws fasten Faucet Automator cover to base 10 Faucet Automator FA400 using supplied fasteners 11 Install shank hose to Faucet Automator s water outlet top 12 Align groove in sensor wire plug with pin in Faucet Automator FA400 sensor receptacle ...

Страница 2: ...ore the desired results are attained 4 When satisfied with sensor range place the rubber plug and enclosure cover back on Please note Sensors that are adjusted for longer range may be triggered unnecessarily by individuals walking in front of sink Please adjust sensor range with that in mind Flow Rate Adjustment Flow rate is governed by supply pressure and the type of aerator used on the faucet Wh...

Страница 3: ...mbing professional Faucet continues to run for 30 60 seconds after hands are removes then shuts off This very rare condition generally occurs due to over sensitivity on the part of the sensor system water pressure well above 70psi and an over lit bathroom environment This condition is always field curable 1 Turn down water flow rate see water flow rate adjustment 2 Replace aerator with 0 5 GPM aer...

Страница 4: ... scalding injury 4 Important Before connecting supply line to Faucet Automator purge both hot and cold water lines for at least one minute each at high volume Purging water lines clears out dirt and debris that would otherwise find its way to screen filter within the solenoid valve 5 Important Do not use pipe putty on water connection to faucet Pipe putty may cause immediate and irreversible damag...

Страница 5: ...MAC FAUCETS Installation Drawings 5 ...

Страница 6: ...Faucet Automator Model FA400 6 ...

Отзывы: