13
Attached components type list
Mode
MMA 315G
MMA 400G
Rated current of Power
switch
32A
40A
Cable
Input side
≥2.5mm
2
≥4mm
2
Output side
35mm
2
50mm
2
Earth cable
≥2.5mm
2
≥4mm
2
Electrode holder
Electrode holder
above 500A is
suggested.
Electrode holder
above 500A is
suggested.
If distance of work piece and machine is too far (500-100m), and the cables (torch
cable and earth cable) are too long, please choose cable of bigger section to
minimize the reduction of the voltage.