DEURAUTOMATEN
7. DATA INSTELLINGEN
Code
Pn00
Quit programing
LED upright display/ inverted display
Opening speed(full energy mode)
Closing speed(full energy mode)
Opening speed(Low energy mode)
Closing speed(Low energy mode)
Braking opening angle
Braking closing angle
Full opening angle
Hold-open time
Starting delay time
Locking delay time
Locking type
Push and go function
Holding force(closed)
Closing force
Anti-clamp sensitivity when opening
Anti-clamp sensitivity when closing
Working mode
Opening force(Low energy mode)
Closing force(Low energy mode)
Opening force(Full energy mode)
Closding force(Full energy mode)
Wind stack mode
(
The motor working
mode when door open by wind
)
Limited agnle(when the door open by wind
and theopening angle is bigger then limited
angle,motor will start to close door)
setting angle( the angle when door closing
at this position the motor stop working)
wind stack mode
Master/slave door
The operating way at manual mode
Toggle mode
Aux lock type
Pn01
Pn02
Pn03
Pn04
Pn05
Pn06
Pn07
Pn08
Pn09
Pn10
Pn11
Pn12
Pn13
Pn14
Pn15
Pn16
Pn17
Pn18
Pn19
Pn20
Pn21
Pn22
Pn23
Pn24
Pn25
Pn26
Pn27
Pn28
Pn29
Pn30
Pn32
Pn33
Pn34
Pn31
Function
Setting range
00
,
01
12~52
10~41
10~26
8~20
5-45
5-45
45-99
0-30
0-7
0-7
00
,
01
00
,
01
01-15
15-30
02-37
02-25
00-01
11-32
02-06
18-40
06-16
00, 01
,
02
01-45
01-20
00
,
01
00
,
01
00
,
01
00
,
01
00
,
03
Default
00
5
2
00
00
01
00
00
00
40
30
20
15
20
10
90
3
4
4
00
00
05
16
10
12
00
18
02
35
08
00
:
door closed and keep 2.5s
,
then motor stop working
01
:
door closed, then motor stop working immediately
02
:
close at the setting angle, then motor stop working
Degree/s
Degree/s
Degree/s
Degree/s
5 degree to 45 degree
5 degree to 45 degree
5 degree to 45 degree
1=1S
1=0.3S
(
Single open: Starting delay timeDouble open: Setting "Starting delay time" on
Master door; Setting "Interval time between the opening of the two doors" on Slave door
)
1=0.3S
00
:
active to lock
01: automatic lock when closed
00
:
not working
;
01
:
working
0-7.5KGS
The force to keep the door closed
when door open by wind.
00:Full energy 01: Low energy
1=0.04S
2~8KG
2~5KG
4~18KG
4~12KG
1=1 degree
1=1 degree
00
:
not working; 01
:
working
00
:
master door
;
01
:
slave door
00
:
all terminals don't working
01
:
active to open, and close by spring
00
:
Active to open, then closing automatically
01
:
Active to open, active to close
1=0.04S
Description
Data setting
Top scan setting
00
00-07
Check the details at Page 18
1=0.12S
RESET
Pn35
00
00
,
01
Set Pn35=01, then go to default value
R:Change this data and
restart the controller
R:Change this data and
restart the controller
R:Change this data and
restart the controller
R:Change this data and
restart the controller
R:Change this data and
restart the controller
R:Change this data and
restart the controller
Must connect to
the "sensor"terminal
00: Fail safe electronic lock 01: Fail secure electronic lock
02: Fail safe strike lock 03:Fail secure strike lock
To prevent an uncomplete opening cycle, the door can moving at
low speed when the sensor detect the wall 00: Disabled 45-106
:
Adjustable 45 ° ~ 105 °
,
Turn this function on from the set open ing Angle
Interval time between the closing of the two doors
(Setting on Master door)
00-15
05
Top scan sensor, slow motion
area in opening
Save the previous failure code
00
--
Save the previous failure code
106
45-106
t +31 88 500 2800
28
SD500TD-T110424