191
t +31 88 500 2800
www.maaslandgroep.nl
PROGRAMMING
TERMS
What is meant by MASTERCODE, USER CODE AND USER CARD?
* The mastercode is a code that must always consist of 6 to 8 digits. This code is needed to make changes to the
keypad. The default code is 999999. We strongly recommend to change it immediately, make a note of it and store it in
a safe place. Make sure that only those who can make changes can see this code.
* A user code is a code that can be programmed at an address of 1-600. With this code the connected electrical lock can
be operated by a user. Note these codes, including the address and to whom this code was issued, so that a single
code (user) can later be removed from the keypad.
* A user card is a card that can be programmed at an address of 1-600. With this card the connected electrical lock can
be operated by a user. Also note these card numbers, including the address and to whom this card has been issued, so
that a single card (user) can later be removed from the keypad.
SYSTEM SETTINGS
CHANGE MASTERCODE
The default mastercode is 999999 and it can be changed as follows.
*
999999
#
00 new mastercode
#
new mastercode
#
*
PAY ATTENTION! This code must consist of a minimum of 6 digits and a maximum of 8 digits
SETTING OPERATION KEYPAD
The keypad is set as standard for operation with the external electronics. The keypad can also function without
these external electronics or with two keypads on both sides of the door.
*
mastercode
#
31 0
#
*
Wiegand reader
*
mastercode
#
31 1
#
*
For use without external electronics and relay 1 active
*
mastercode
#
31 2
#
*
For use without external electronics and relay 1 and 2 active
*
mastercode
#
31 7
#
*
For use with external electronics (factory default)
If the Wiegand reader option is selected, the format of the data can be adjusted in the following way. By default
it is set to 26 bits.
*
mastercode
#
32 26-37
#
*
OPTIONAL SETTINGS
BUZZER FUNCTION
*
mastercode
#
41 0
#
*
Buzzer off except during programming
*
mastercode
#
41 1
#
*
Buzzer sounds when key is pushed (factory default)
BACKLIGHT KEYPAD
*
mastercode
#
42 0
#
*
Backlight is off
*
mastercode
#
42 1
#
*
Backlight always on
*
mastercode
#
42 2
#
*
Backlight in sleepmode en goes on by pressing keys or using cardreader
(factory default)
LED LIGHT
*
mastercode
#
43 0
#
*
LED is off in standby
*
mastercode
#
43 1
#
*
LED is on in standby (factory default)