Product View -------------------------------------------

Product Features -------------------------------------- 

Technical Specifications -----------------------------

Precautions before Use ------------------------------

Product Functions -------------------------------------

Maintenance and Precautions ----------------------

Dear customer,

We appreciate your support purchasing our product – digital torque adapter. In order to learn 

the advantages of the product well, please kindly read the instruction carefully before you 

adjusting to any settings. Also please keep this manual for your reference in the future.

4.1 Battery installation

4.1.1 Open battery cover.

4.1.2 Insert battery, make sure

polarity is correct.

4.1.3 Replace the battery cover.
4.2 Low Voltage Notification

If the system detects a voltage level of less than 2.3V, a

battery icon will appear at the upper right corner of the

screen, and the system will shut down a few seconds

later.

1. Product Overview

As a result of torque measurement and calibration requires strict certification, torque 

instruments must possess good temperature, precision, and resolution capabilities, and must 

also have the ability to correct for disturbances (ESD and EMI). And while the characteristics 

of peripheral components must meet specification requirements, measurement chip 

specifications must also meet requirements. Because of this, the simplification of peripheral 

passive elements can enable an instrument to accurately measure torque values, which will 

not only save cost, but also improve maintenance and assembly quality, and lessen the 

chance of damage to the used objects.

2. Product Features

Simple multifunctional operation, vibration resistance, can preset torque value, unit switching,

mode switching, memory & storage, digital up & down increments, power-saving mode, LED

flashing & audible alarm, etc...

3. Technical Specifications

4. Before using the adapter

This product provides international standard metric units of Nm, metric units of Kgf.cm, and 

British units of lbf.in and lbf.ft. The units will change each time the U/S key is pressed, in the 

order of Nm,Kgf.cm, lbf.in, and lbf.ft; the preset units are Nm.

5.2 Unit Switching

 (F) Mode: (preset as tracking mode at time of first use)

After setting a value (assuming the value is 50Nm), the force applied by the wrench 

will gradually increase from 0000. When force is applied, the displayed value will 

change as the user applies different amounts of force; the reading will increase as 

force increases, and decrease as force decreases. The reading will jump to 50Nm 

when the user relaxes his grip and lets up.

5.4 (F) Mode/ (K) Mode/(A) Mode (Angle Series)

Values can be freely selected as long as force is not being measured or memory selection 

has not been performed. After completing torque measurement in either mode, the selected 

value can be displayed.

5.5 Measurement Range Selection

Pressing the ▲ (up) key once will cause the value on the far right to increase by one; 

pressing the key continuously will cause the value to increase continuously. Pressing the 

▼ (down) key once will cause the value on the far right to decrease by one.

5.6 

▲( U P ) / ▼ ( D O W N ) selection

(There will be a beep each time a key is pressed.)

 In Track mode, the two LED light will function as green and red. Assume that the torque 

value is set at 20Nm. When the user starts applying force to the wrench, the value changes 

from 0000. When the force reaches 80% of the set value, the green light starts to flash, and 

the buzzer starts to sound. When the torque value approaches the set value, the green light 

flashes faster and the buzzer sounds faster. When the force reaches 100% of the set value, 

the green light comes up permanently, and the buzzer sounds continuously. When the force 

exceeded the set value(101%) , the red light comes up, and the buzzer continues to sound. 

The value decreases when the force applied to the wrench is decreased.

5.7 

LCD Backlights Warning & Buzzers

 (K) Mode:

After the value is selected (assuming 50Nm is selected), when the wrench is applied with 

force, the value increases from 0000 upwards. When the force is applied by the force, the 

displayed value will change according to the force of the applying force, and after the force is 

completely stopped, the value is displayed. For the final torque value, flashes for 10 seconds. 

After 10 seconds, continue to apply the torque value will automatically accumulate (at this 

time, any action and button are invalid). After 10 seconds, no force will continue to return to 

the selected value, or press C can be returned to the selected value.

(A) Mode (Angle series):

After setting a degree (assuming is 50°), the force applied by the wrench will gradually 

increase from 0°. When the force is exerted, the displayed value will change according to the 

angle of the force applied, and the force will stop completely. The display value is the final 

angle value and torque value. The angle value and torque value are interactively displayed. 

Flashing for 10 seconds. Continue to force the angle value within 10 seconds will 

automatically accumulate (in this case, any action and buttons are invalid). After 10 seconds, 

no continue to force automatically return to the selected value, if not press C key to clear, 

then the next time the force is applied, the angle value will continue to accumulate from the 

previous value, until over the selected value will automatically clears the accumulated value, 

switch mode and shutdown it also clears the angle accumulated value.

All memory data sets are preset as the maximum value. To set a memory value, press the 

M key, and the digit on the far right of the M-01 display will begin to flash; use ▲ (up) or 

▼ (down) to select the memory data set (up and down keys can be held down for 

continuous increase or decrease). Press the M key after selected, will stop flash and leave 

the function.

5.3 Memory Function

Power ON

 Press the C button to turn on the wrench. Next, the backlight comes up, and all 

the text on the LCD flashes. After displaying 0000 from left to right, the wrench enters into 

operation mode.

Turn Off :

 Press C key and hold 3 seconds to switch off.

Clear :

 Press C key to reset (when device turned on).

5.1 Power and Reset

The function panel have 6 buttons, the

function is as follow:

Button

Function

C

Power & Reset

U/S

Unit Selection

M

Memory Selection

F/K/A

Mode Switch

A-Mode (Angle series)

Number Increasing (UP)

Number Decreasing(DOWN)

5. Product Functions

2.1 Digital torque, angle degree and default value display.

2.2 LCD backlight display.

2.3 Can be used in both clockwise and counterclockwise directions.

       Accuracy: CW±2% (clockwise) CCW±3% (counterclock- wise)

2.4 Can store 30 memory default values.

2.5 Power saving mode (enters power-saving mode after 2 minutes).

2.6 Have buzzer and LED backlight indicators.

2.7 Low voltage detector (reminds user of battery life).

2.8 Unit : Nm/kgf.cm/lbf.in/lbf.ft

Function and Name for Each Parts

Upper Cover

Down Cover

Battery cover

Extension bar 

square hole

Extension bar 

square head

Function Button

LCD display 

monitor

LED indicators.

Buzzer

Torque value display

Unit display

Memory group display

F/K/A(Track/Peak/Angle )

Percentage display

Battery life display

 *1 Torque Accuracy

According to ISO6789:2003, a specified measuring 

range from 20% to 100% of the maximum torque value of the respective tool.

lb-in

lb-ft

Nm

Kg.cm

1

1 lb-in

1 lb-ft

1 Nm

1 kg.cm

0.083

0.113

1.152

12

1

1.356

13.83

8.851

0.737

1

10.2

0.868

0.072

0.098

1

P.01

P.02

P.03

P.03

P.04

P.11

User Must Read and Understand the Operator’s 

Manual. Save These Instructions For Future Reference.   

CAUTION:

GTA - Digital Angle Torque Adapter Series

Operator’s Manual

Angle accuracy : ±2° (Angle series)

(A mode - 

Angle series only)

 *2 Angle Accuracy

1° for 90° rotation at 45°/sec.

1

2

3

4

5

6

7

8

9

10

11
12
13

14
15

Model Type

Memory Capacity

Torque Accuracy*1

Angle Accuracy*2

Max. angle measure

LED Indicator

Operation Modes

Unit

OperatingTemperature

Storage Temperature

Drop Test

Vibration Test

Life Test

Environmental test

EMC Test

30 Sets

-10℃ ~60℃

-20℃ ~70℃

1m

10 G

10000 cycle

Pass
Pass

Battery life

(Continuousoperation)

Battery life

(Standby Mode)

Humidity

CW:±1.5% CCW:±2.5%

Angle Series

General Series

+/- 2°

720°

2 LED(1 Green + 1 Red )

Track(F) / Peak hold(K) / Angle(A)

Nm、kgf.cm、lbf.in、lbf.ft

48 hrs.

1 year

Up to 90% non-condensing

N-m

Angle series installs two AAA batteries.

(Can use zinc-carbon or alkaline battery.)

General series install single CR2032 battery.

The adapter horizontally set, press the C key to boot, backlit LCD text full flash, from left to right shows 

0000, the adapter automatically detects whether there is to stand still, if such as not standing, LCD from 

left to right continuous display 0000, until the adapter is completely static, the four 0 at the same time 

display three times, enter the operating mode.

When this product is used for the first time, it will display the product's maximum operating value after 

entering the operating mode. The units are preset as N-m, the memory will display the first set, the mode 

will be tracking mode T, and the battery scale will show the voltage detected at that time (all 30 memory 

data sets will have the same preset value).