background image

18

Premier 4-4-2 Atlantic E-6 Steam Engine

Troubleshooting Proto-Sound

®

 2.0 Problems

Although Proto-Sound 2.0 has been designed and engineered for ease of use,
you may have some questions during initial operation.  The following table
should answer most questions.  If your problem cannot be resolved with this
table, contact M.T.H. for assistance (telephone: 410-381-2580; fax:
410-423-0009; [email protected], 7020 Columbia Gateway Drive,
Columbia MD 21046-1532).

Starting Up

Horn

Bell

Coupler

Remedy

Remedy

Remedy

Remedy

Remedy

When I first turn the power on, the 
engine will not begin to run.  I have to 
turn the throttle off and then on again 
to get the engine to operate.

When I press the whistle button, the 
bell comes on instead.

I can’t get the horn to blow when I 
press the whistle button.

I can’t get the bell to ring when I press 
the bell button.

The bell won’t work on a separate bell 
button.

When I try to fire the coupler, PSA 
starts.

The Proto-Coupler won’t let the engine 
uncouple on the fly.

When I press the whistle button, the 
bell sounds.

Reverse the transformer leads.

You may be pressing the button too 
quickly. Try pressing the whistle button 
more slowly, taking approximately one 
full second to fully depress the button.

You may be pressing the button too 
quickly. Try pressing the bell button 
more slowly, taking approximately one 
full second to fully depress the button.

Reverse the transformer leads.

Check the wiring of the separate 
button.

You are waiting too long between 
whistle button presses.

Try lubricating the coupler knuckle 
with a dry graphite lubricant. Do NOT 
use oil.

This is normal behavior.  To prevent 
accidental high-speed start-ups, Proto-
Sound 2.0 is programmed to start up 
in neutral anytime track power has 
been turned off for several seconds.  
See the "Basic Operation" section for 
more details.

Содержание PREMIER 4-4-2 ATLANTIC E-6

Страница 1: ...atible with most other 3 rail locomotives rolling stock and accessories This locomotive is equipped with Proto Sound 2 0 with Digital Command System DCS This new system will allow you to operate your...

Страница 2: ...upler Operation 8 Speed Control 8 Lock into a Direction State 9 Reset to Factory Defaults 9 Automatic Sounds 9 Maintenance 10 ProtoSmoke Unit Operation 10 Lubrication and Greasing Instructions 12 Loco...

Страница 3: ...gine to the OFF position see Fig 4 Running the engine without a primed smoke unit may cause damage See the ProtoSmoke Unit Operation section of this book for more information on smoke unit maintenance...

Страница 4: ...tinue to ring from the time you turn it on until you press and release the button again to turn it off Direction Your train is programmed to start in neutral The first direction after neutral upon sta...

Страница 5: ...ou should read these instructions thoroughly before using Proto Sound 2 0 features in order to prevent harm to yourself or your equipment Activating Proto Sound 2 0 Conventional Mode Features Proto So...

Страница 6: ...sequence of PSA The reverse unit is temporarily disabled so that the train will not move as you use the Direction button to trigger the sounds and Proto Sound 2 0 has disabled operator control over th...

Страница 7: ...ped the engine to run the PSA Otherwise the engine without PSA will begin vibrating on the track as its motors strain to move the train since they cannot be automatically disabled during the PSA cycle...

Страница 8: ...the run and the engine will maintain the speed you set While the engine is programmed to start with the speed control feature activated you can opt to turn it off This means the engine s speed will fa...

Страница 9: ...rn 3 bells code to return the engine to its normal state even if the engine is kept without power for extended periods of time Reset to Factory Defaults To override the settings you currently have ass...

Страница 10: ...GB or LVTS fluids Do not overfill the unit or the fluid may leak out and coat the interior engine components If you choose not to add the fluid or have already added the fluid but choose to run smoke...

Страница 11: ...he locomotive s body see Fig 5 After removing the chassis and inspection cover screws lift the inspection plate away and inspect the wick If it is darkly discolored and hard it should be replaced Repl...

Страница 12: ...hillips screws marked GREASE located at each set of wheels 3 Use a grease tube dispenser to put a small amount approx 1 2 ml of lithium based grease into the gearbox 4 Replace the screw You should als...

Страница 13: ...flathead screwdriver to pry away any remains 3 Slip the new tire onto the wheel You may find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 4 If you twist the tire...

Страница 14: ...s attaching the headlight shell and bracket to the boiler 4 Locate and unplug the headlight wires from the connector 5 Remove the light bulb from the rear of the headlight shell by gently pulling the...

Страница 15: ...5 Remove the screws securing the cylinder saddle Do not remove the cylinder saddle Be careful of the siderods and vale gear coming loose when the cylinder saddle is lifted 6 Guide the wires for the LE...

Страница 16: ...screw Remove the one front and two rear body mount screws and carefully lift the boiler from the chassis being careful to leave the wires attached 2 Unplug the black wires from their connector You mu...

Страница 17: ...rned off test the battery to determine whether it should be recharged or replaced Put the engine in neutral and leave the track voltage at 12 volts for 15 minutes If the garbled or distorted sounds ar...

Страница 18: ...ll to ring when I press the bell button The bell won t work on a separate bell button When I try to fire the coupler PSA starts The Proto Coupler won t let the engine uncouple on the fly When I press...

Страница 19: ...is locked into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2 0 volum...

Страница 20: ...perator cycles through the PSA sequences PSA is programmed to start ringing the bell at that point After approximately 12 rings of the bell it will automatically turn off Because PSA must control vari...

Страница 21: ...att Standard Lionel 1043M U A 5 16v 90 Watt Standard Lionel 1044 U A 5 16v 90 Watt Standard Lionel 1053 U A 8 17v 60 Watt Standard Lionel 1063 U A 8 17v 60 Watt Standard All Trol Left Terminal Right T...

Страница 22: ...ke each engine outputs and matches smoke to locomotive speed Locomotive Lighting Control Controls locomotive headlights marker and interior lights beacon lights ditch lights and MARS lights Emergency...

Страница 23: ...can determine locomotive values for consist make ups allowing multiple locomotives belonging to a consist to operate together Query Locomotive Information User can query locomotive programming to lea...

Страница 24: ...ecautions should be followed including the following Read this manual thoroughly before using this device M T H recommends that all users and persons supervising use examine the hobby transformer peri...

Страница 25: ...___________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________...

Страница 26: ...___________________________________________ ___________________________________________________ ___________________________________________________ _______________________________ ____________________...

Страница 27: ...___________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________...

Страница 28: ...tacting M T H for your Return Authorization number 3 Please make sure you have followed the instructions carefully before returning any merchandise for service Limited One Year Warranty All M T H prod...

Отзывы:

Похожие инструкции для PREMIER 4-4-2 ATLANTIC E-6