R1M-GH

P.  / 4

EM-5657 Rev.7

MODBUS WIRING CONNECTION

R1M

T1

T2

T3

T4

R1M

T1

T2

T3

T4

T1

T2

T3

T4

R1M

CONNECTOR

RS-232C

RS-485

*

1

*

1

*

1. Internal terminating resistor is used when the device is at the end of a transmission line.

*

2. Install shielded cables to all sections and ground them at single point.

*

2

FG

RS-485

TERMINAL CONNECTIONS

Connect the module referring to the connection diagram.
Attach the CJC sensor together with input wiring to the input screw terminals.  The sensor is calibrated for each particular 
module and not interchangeable with another.  Check the serial numbers of the module and sensor.

RS-232C

T3

T4

T2

T1

T7

T6

T5

Term.

Resist.

Output

Circuit

When the device is located at the end of a transmission line via twisted-pair cable, 

(when there is no cross-wiring), close across the terminal T2 – T3 with the attached

jumper pin (or with a leadwire).
When the device is not at the end, remove the jumper pin.

Remark 1: This device is not designed to cancel noise included in the input signals.
Be careful to eliminate such noise by using shielded cables.
Remark 2: Be sure to maintain the same potential at all the common negative 
terminals for DC input.

*

9

8

7

6

5

4

3

2

1

10

12

11

13

15

14

16

17

18

20

19

21

22

23

24

25

27

26

28

29

30

31

32

33

35

34

36

TRIGGER INPUT

T/C INPUT

+

DC INPUT

INPUT 1

+

INPUT 2

INPUT 3

INPUT 4

INPUT 5

INPUT 6

INPUT 7

INPUT 8

INPUT 9

INPUT 10

INPUT 11

INPUT 12

INPUT 13

INPUT 14

INPUT 15

INPUT 16

CJC

Sensor

+

ext. wire

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

Power
Circuit

Input

Circuit

+

Shielded Twisted-pair Cable

To Other
I/O Modules

Jumper

*

FG

U (+)

V (–)

POWER

D-SUB CONNECTOR

ABBR. 

PIN NO.  EXPLANATION OF FUNCTION

BA (SD) 

Transmitted Data 

 

 

BB (RD) 

Received Data   

 

 

AB (SG) 

Signal Common

CB (CS) 

Clear to Send   

 

 

CA (RS) 

Request to Send

 

Not Used. 

 

 

 

 

DO NOT connect.  Connecting may 

 

cause malfunctions. 

 

 

 

9

1

5

6

9

 RS-232C INTERFACE

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Содержание R1M Series

Страница 1: ...rotocol Modbus RTU Protocol Modbus RTU Refer to Modbus Protocol Reference Guide EM 5650 for supported functions RS 232 C Standard Conforms to RS 232 C EIA Transmission distance 10 meters max RS 485 St...

Страница 2: ...700 C or 1292 F The described accuracy may be partially not satisfied when the temperature ranges below 0 C STANDARDS APPROVALS CE conformity EMC Directive 2004 108 EC EMI EN 61000 6 4 2007 EMS EN 61...

Страница 3: ...e When the device is not at the end remove the jumper pin Remark 1 This device is not designed to cancel noise included in the input signals Be careful to eliminate such noise by using shielded cables...

Страница 4: ...slave 04 Read Input Registers X Collected data from the field by the slave 05 Force Single Coil X Digital output from the slave 06 Preset Single Registers X General purpose register within the slave...

Страница 5: ...17 48 F Reserved for AO in engineering unit 145 160 Y Y I I O type No 161 176 Y I Burnout type 161 168 for Type J3 0 No burnout 1 Upscale 2 Downscale 4 I 16 bit integer F 32 bit floating B16 16 byte...

Страница 6: ...E A D DATA Decimal DC 20V 20000 5V 5000 1V 10000 0 8V 8000 0 2V 20000 50mV 5000 10mV 10000 Thermocouple Temperature x 10 RTD Temperature x 10 Potentiometer 0 100 2000 0 500 0 1k 0 10k BIT NAME DESCRIP...

Страница 7: ...00 to 600 C 0X1B L 200 to 900 C 0X1C P Platinel II 0 to 1395 C R1M J3 RTD input 0X30 JPt 100 JIS 89 200 to 500 C 0X31 Pt 100 JIS 89 200 to 660 C 0X32 Pt 100 JIS 97 IEC 200 to 850 C 0X33 Pt 50 JIS 81 2...

Страница 8: ...istance between the PC and the R1Ms is long insert an RS 232 C RS 485 Converter for isolation RS 232 C RS 232 C RS 485 Converter model R2K 1 Specifications are subject to change without notice Ruggh l...

Страница 9: ...urce connected to the unit and TDK Model ZCAT3035 1330 or equivalent for the RS 232C cable are recommended The equipment must be installed such that appropriate clearance and creepage distances are ma...

Страница 10: ...5 T1 T2 T3 T4 T5 T6 T7 CJC Sensor model CJM RS 485 Connector Address Setting Rotary SW Configurator Jack Specifications Marking Power Terminals RS 232C 9 pin Connector RUN Indicator LED DIN Rail Adapt...

Страница 11: ...t the end remove the jumper pin Remark 1 This device is not designed to cancel noise included in the input signals Be careful to eliminate such noise by using shielded cables Remark 2 Be sure to maint...

Страница 12: ...alibration procedure is explained below CALIBRATION Warm up the unit for at least 10 minutes Apply 0 25 50 75 and 100 input signal Check that the output signal for the respective input signal remains...

Отзывы: