EM-5958  Rev.7  P. 5 / 5

 

A/D CONVERSION DATA

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Ch. (1st)

SIGN

BIT

INPUT 1  A/D CONVERSION DATA

Ch. (1st+1)

SIGN

BIT

INPUT 2  A/D CONVERSION DATA

Ch. (1st+2)

SIGN

BIT

INPUT 3  A/D CONVERSION DATA

Ch. (1st+3)

SIGN

BIT

INPUT 4  A/D CONVERSION DATA

Ch. (1st+7)

SIGN

BIT

INPUT 8  A/D CONVERSION DATA

Ch. (1st+11) SIGN

BIT

INPUT 12  A/D CONVERSION DATA

Ch. (1st+15) SIGN

BIT

INPUT 16  A/D CONVERSION DATA

The R1D reserves 16 words at the Output Data Area (data 
sent from the R1D to the master) for the specified node ad-
dress and sets the input data at this area.  The Input Data 
Area (data sent to the R1D from the master) for the same 
node address is only reserved but unused.

CHECKING

1) Terminal wiring:  Check that all cables are correctly con-

nected according to the connection diagram.

2) Power input:  Check supply voltage across the terminals 

T6 – T7.

3) Input:  Check that the input is within 0 – 100% of full-

scale.

4) DIP SW setting:  Check that all switches are set correctly.

ADJUSTMENT PROCEDURE

This unit is calibrated at the factory to meet the ordered 
specifications, therefore you usually do not need any cali-
bration.

MAINTENANCE

Regular calibration procedure is explained below:

 

CALIBRATION

Warm up the unit for at least 10 minutes.  Apply 0%, 25%, 
50%, 75% and 100% input signal.  Check that the output 
signal for the respective input signal remains within accu-
racy described in the data sheet.  When the output is out of 
tolerance, please contact M-System’s Sales Office or repre-
sentatives.

EDS

DeviceNet Electronic Data Sheet

Author:S. Okazaki

[File] 

DescText 

= “This is for R1D_GH2”;

 

CreateDate  = 01-18-02;

 

CreateTime  = 00:00:00;

 

ModDate 

= 03-10-14;

 

ModTime 

= 00:00:00;

 

Revision 

= 1.0;

[Device]  VendCode 

= 184;

 

VendName 

= “M*System  Co.,Ltd.”;

 

ProdType 

= 0;

 

ProdTypeStr =  “Generic  Device”;

 

ProdCode 

= 22;

 

MajRev 

= 1;

 

MinRev 

= 1;

 

ProdName 

= “R1D_GH2”;

 

Catalog 

= “N/A”;

[IO_Info] Default 

=  0x0001;

 

PollInfo 

= 0x0001,1,1;

 

Input1 

= 32,0,0x0001,

 

 

 “”,6,

 

 

  “20 04 24 02 30 03”,“”;

 

Output1 

= 0,0,0x0001,

 

 

 “”,6,

 

 

  “20 04 24 01 30 03”,“”;

[ParamClass]

[Params]

[EnumPar]

[Groups]