114
DL8 USERS
MANUAL EM-7691-B Rev.24
10.4 TEST TRANSMISSION
FTP test transmission is available using the DLCFG. Follow the procedure as explained below.
1.Click
Maintenance
2.Click
3.Click
Main Window
The DL8 sends data stored in the memory and at the moment of the transmission.
Time
Storing Interval
Storing Data
Test Transmission
Test: Sending stored data plus
data sampled at the moment of test
Next regular transfer: Sending data stored
after the test till the moment of transfer
NOTE
• If test transmissions are repeated multiple times, data sent in the following regular transmission is the one from the
last test to the scheduled transmission time.
• If the FTP client test file name is the same as that of the regular transmission, the older one is overwritten.
10.5 STATUS VERIFICATION
You can check transmission status via terminal software in the same way as in the cloud access mode of the web server.
Refer to 8.8.3 STATUS VERIFICATION.
NOTE
• To verify transmission status while conducting a test transmission, connect the DLCFG via network.
Refer to 14.3 DLCFG VIA NETWORK.