INSTRUCTION MANUAL

Devicenet

®

 I/O MODULE

(PNP discrete input, 32 points, MIL connector)

MODEL

R7F4HD-DA32B

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Discrete input module .........................................................(1)
DIN rail mounter slider ......................................................(2)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

 

EDS FILE

EDS files are downloadable at M-System’s web site: https://
www.m-system.co.jp

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVES

• The equipment must be mounted inside the instrument 

panel of a metal enclosure.

• The actual installation environments such as panel con-

figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated 
in a panel system.  The user may have to review the CE 
requirements in regard to the whole system and employ 
additional protective measures to ensure the CE conform-
ity.

 

GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power 

supply and input signal for safety.

• Before you remove the terminal block or mount it, make 

sure to turn off the power supply and input signal for 
safety.

• DO NOT set the switches on the module while the power 

is supplied. The switches are used only for maintenance 
without the power.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C 

(14 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

• Observe at the minimum of 10 mm left and right the 

units for heat dissipation when mounting vertically.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

• Be sure to close the terminal cover for safety.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

DeviceNet is registered trademark of ODVA.

Содержание Devicenet R7F4HD-DA32B

Страница 1: ...to the whole system and employ additional protective measures to ensure the CE conform ity GENERAL PRECAUTIONS Before you remove the unit or mount it turn off the power supply and input signal for sa...

Страница 2: ...supply DISCRETE INPUT STATUS INDICATOR LED LED green indicators shows the signal status ON LED ON OFF LED OFF NODE ADDRESS The left switch determines the tenth place digit while the right switch does...

Страница 3: ...on power supply Input Terminal Assignment 39 40 1 2 Applicable connector XG4M 4030 Omron PIN No ID FUNCTION PIN No ID FUNCTION 1 VS Exc supply 2 VS Exc supply 3 VS Exc supply 4 VS Exc supply 5 X31 Inp...

Страница 4: ...the upper hook of the unit from the DIN rail A C B SURFACE MOUNTING 1 Insert the two DIN rail mounter sliders until it clicks once as shown below A A 2 Mount the unit with M4 screws referring to the...

Страница 5: ...6 6659 8201 Fax 81 6 6659 8510 E mail info m system co jp EM 8006 B P 5 9 TERMINAL CONNECTIONS Connect the unit as in the diagram below EXTERNAL DIMENSIONS unit mm inch 115 4 53 55 2 17 75 2 95 123 4...

Страница 6: ...AN_H Drain CAN_L V 25 38 22 26 24 27 32 28 29 33 31 34 30 35 36 37 X1 VS VS X15 X7 X14 X6 X13 X5 X9 40 39 X0 X8 X12 X4 X11 X3 X10 X2 VS 23 VS 1 5 18 2 6 4 7 12 8 9 13 11 14 10 15 16 17 X17 VS VS X31 X...

Страница 7: ...can be monitored with the PC configurator software model R7CFG Refer to the users manual of the software for detailed operations DATA ALLOCATION Begin 0 1 R7F4HD DA32B x0 x15 R7F4HD DA32B x16 x31 Outp...

Страница 8: ...t 12 Input 28 Input 9 Input 25 Input 10 Input 26 Input 14 Input 30 Input 15 Input 31 Input 13 Input 29 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1 O...

Страница 9: ...OUTPUT DATA 1 R7F4HD to master INPUT DATA 2 Master to R7F4HD R7F4HD DA32B 1 0 STATUS Turn SW1 3 to ON to include the status signal in the transmission data For details refer to STATUS in I O DATA DESC...

Отзывы: