ISOLATION AMPLIFIER

(small size, input isolation, DIP type)

MODEL

20VS8-202N

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, check the 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 PACKAGE INCLUDES:

 Amplifier ....................................................................... (1)

 MODEL NO.

Confirm that the model number described on the product is 
exactly what you ordered.

 INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 POWER INPUT RATING

• Operational voltage range & power consumption

  15V DC rating: Rating ±5%, approx. 7.5mA (with no load)

 ENVIRONMENT

• Indoor use
• Do not install the unit where it is subjected to continuous 

vibration.  Do not apply physical impact to the unit.

• Environmental temperature must be within -25 to +85°C 

(-13 to 185°F) with relative humidity within 30 to 90% RH 

in order to ensure adequate life span and operation.

 WIRING

• Do  not  install  cables  (power  supply,  input  and  output) 

close to noise sources (relay drive cable, high frequency 
line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 INSTALLING THE MODULE

When it is installed on the printed wiring board, land diam-

eter ø1.6 and through-hole ø1.0 are recommended.

 AND ....

• The unit is designed to function as soon as power is sup

-

plied, however, a warm up for 10 minutes is required for 

satisfying complete performance described in the data 
sheet.

• With  voltage  output,  do  not  leave  the  output  terminals 

shortcircuited for a long time.  The unit is designed to en-
dure it without breakdown, however, it may shorten ap-
propriate life duration.

CHECKING

1)  Terminal wiring: Check that wiring is correctly connect-

ed according to the connection diagram.

2)  Power input voltage: Check voltage across the pins.
3)  Input: Check that the input signal is within 0 – 100% of 

the full-scale.

4) Output: Check that the load resistance meets the de-

scribed specifications.

TERMINAL CONNECTIONS

 EXTERNAL DIMENSIONS mm (inch) 

max. 53.3 (2.1)

17.8 (.7)

12.7 (.5) 

40.6 (1.6)

2.54 (.1)

40.6 (1.6)

max. 8.9

(.35)

min. 2.5

 (.1)

17.8 (.7)

12.7 (.5)

1 2 3

18

22

19

38 37 36

20

0.46 (.02) dia.

20

19

18

3

2

1

Output (+)

Output COM (–)

Inverting Input

38

37

36

Feedback

Reference Voltage Source (+)
Reference Voltage Source (–)

Power Supply (–)

Input COM (–)

Non-inverting Input

22

Power Supply (+)

PIN ASSIGNMENTS