M Design LUN A1000 RD GOLD GAS Скачать руководство пользователя страница 1

1

                      LUNA 

  1000 - 1300 RD GOLD GAS

                    INSTRUCTION FOR INSTALLATION AND USE

Passion for fire

English 06-2012

Содержание LUN A1000 RD GOLD GAS

Страница 1: ...1 LUNA 1000 1300 RD GOLD GAS INSTRUCTION FOR INSTALLATION AND USE Passion for fire English 06 2012 ...

Страница 2: ... I O N I N S T R U C T I O N S F O R T H E M D E S I G N G A S F I R E P L A C E S T H E S U P P L I E R TA K E S N O R E S P O N S B I L I T Y F O R A N Y P O S S I B L E D A M A G E P O O R W O R K I N G A P P L I A N C E S A N D A C C I D E N T A S A R E S U LT O F I N C O R R E C T I N S TA L L AT I O N ...

Страница 3: ...1 3 Electrical connection 7 4 INSTALLING THE CHIMNEY 8 11 5 INSULATION AND FINISHING 12 6 CONVECTION CURRENT 13 14 15 7 MOUNTING A 3 SIDED FRAME 16 8 POSITIONING THE LOGS DIAMOND SAPPHIRE AND WHITE PEBBLES 17 1000RD 18 19 1150RD 20 21 9 FIRST TIME USE 22 10 SAFETY ADVICE AND MAINTENANCE 22 11 STARTPILOT 23 12 USIGN THE MANUAL CONTROL 23 13 SPECIFICATION SHEET 24 25 DRAWINGS 26 27 14 GUARANTEE 28 ...

Страница 4: ... RD GOLD GAS 4 OPEN CLOSING KEY IF SOME DUST OR WASTE IS SEEN ON THE WINDOW INSIDE AND OUTSIDE CLEAN THIS BEFORE THE FIRST USE OF THE FIREPLACE CLEANING THE WIN DOW IS THE ONLY MAINTENANCE ACTION THAT CAN BE DONE BY THE CONSUMER OPEN AND CLOSE THE DOOR ...

Страница 5: ...rder specifications this appliance is designed for natural or propane gas Read the instructions before installing and using this appliance Before installing the furnace please check the local regulations about this type of furnace identification of the type of gas etc and check that the furnace is adapted to your means of installation CAUTION The furnace must be connected to the type of gas mentio...

Страница 6: ...ht of the fireplace by turning the bolt pic 1 A min 3 5 cm B 14 5 cm C min 18 cm The stove may not be placed direct ont the floor to allow natural convection The appertures for the air supply IN is situated underneath the appliances Regulating the height of the appliance The minimal height as from ground to the 4th side frame is 3 5 cm A min The minimal height C min will be 18 cm measured as from ...

Страница 7: ... 3 1 3 ELECTRICAL CONNECTION These appliances are equiped with a radiographic remote control making an earthened 220V socket necessary You should bear in mind that the appliance must be connectes from all electrical supply for thurpose of service ITS OBLIGATORY TO CONNECT AN EARTH CURRENT 3 1 2 GAS CONNECTION The appliances are standard delivered with a 1 2 gas solded connection pic 1 It is always...

Страница 8: ... GOLD GAS 8 PIC 1 ROOF EXIT C31 Ø 150 100 after elbow 90 Ø 200 130 Appliance C min C max Restriction 1000 RD 2 m 10m Ø 75 1300 RD 3 m 10m Ø 75 Ø 200 130 Appliance C min C max Restriction 1000 RD 2 m 10m Ø 75 1300 RD 2 m 10m Ø 75 C Reduction 200 130 150 100 ...

Страница 9: ...D GAS 9 PIC 2 ROOF EXIT VIA EXISTING CHIMNEY C91 It is obligatory to use the sanitation set USSAN with placing Ø200 min Ø 130 Appliance C min C max Restriction HR as from 2 m 1000 RD 2 m 10m Ø 75 1300 RD 2 m 10m Ø 75 This USSAN piece must be saeled at the roof ...

Страница 10: ...all exit wall exit Ø 75 A MIN 1m B 255 elbow min 90 3 DO NOT USE A REDUCTION 200 130 to 150 100 IN THIS CASE IMPORTANT BE CAREFULL EVERY HORIZONTAL PART DOES NOT HAVE AN NEGATIVE INCLINATION pic 5 IN DIRECTION OF OUTLET IT IS EVEN BETTER WHEN POSSIBLE TO HAVE A LITTLE INCLINATION OF 2 OR 3 DEGREES ASCENDING ONLY THE OUTLET MUST BE INSTALLED LIKE PIC 6 TO AVOID RAIN DROPS IN TUBE ...

Страница 11: ...l lenght you will need to place a reduction ring of Ø 75 Appliance Ø 150 100 and Ø 200 130 1000 RD 1300 RD for each 90 bend substract 1 m horizontaly or add 1 m verticaly 1000 RD 1300 RD for each 45 30 15 bend substract 0 5 m horizontaly or add 0 5 m verticaly Ø 200 130 Appliance A min B max C min A B C max 1000 Rd 1 m A C B A 9m 12 m 1300 RD 1 m A C 1 B A 1 10 m FIG 5 ...

Страница 12: ...g check the tightness of the gas pipe and the smoke pipe Once you have checked everything you can perform the final insula ting and finishing operations The built in part of the furnace tends to be very warm Please check that the furnace is not too nar rowly fitted and that there is adequate space for the elimination of hot air For insulation of the furnace we advise you to use M Design insulating...

Страница 13: ...ids give off more heat than others and seeing that a hot air pipe functions in a manner similar to a chimney the one that is hot first has the most draught and therefore becomes hot even more quickly Note a circulation of hot air requires that no under pressure be created in the room A grid that is near the floor pic 2 sees to it that cold air can be drawn in M design has developed its ideal hot a...

Страница 14: ...AS 14 Design Grid outlet with 2 connections OUTLET CONVECTION INLET CONVECTION OUTLET CONVECTION Inlet Grid convection air Inlet Grid convection air Design Grid outlet with 2 connections 2 dm 4 dm Design Grid outlet with 4 connections OR OR INLET CONVECTION Pic 3 ...

Страница 15: ... THE STOVE MAY NOT BE PLACED DIRECT ON THE FLOOR WTHOUT THE FEETS THIS TO ALLOW NATURAL CONVECTION THE APPERTURES FOR THE AIR SUPPLY ARE SITUATED UNDERNEATH THE APLLIANCE EVERY OPENING YOU MAKE MUST BE CONNECTED WITH A FLEXIBLE TUBE dia 150MM see pic below THIS WILL AVOID THE HEATING OF THE ELECTRONIC PART OF THEAPPLIANCE IN OTHER CASE YOU WILL HAVE ERRORCODE F02 OUTLET CONVECTION INLET CONVECTION...

Страница 16: ... an upper and 2 sideframes see pic 2 Before mounting the 3 sided frame remove 4 sided frame lower piece by lift it carefully up Pull out the upper frame and in second way the left and right sideframes Take the left and right side of the 3 sided frame 3 5 7 or 10 cm and slide them in the notches see pic 4 When those are placed in a good way you can adjust the position to the left en to the right an...

Страница 17: ...led down Move the window to the front by pulling it The window tips open at 45 Arrange the materials supplied In accordance with your order you will have either a set of logs diamond sapphire or white pebbles There is an adequate supply of materials Our appliance is approved with these materials so please do not use other products Other decorative products are prohibited in our appliances Please d...

Страница 18: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 18 1 2 3 4 5 6 7 8 9 5 6 7 8 9 1 2 4 3 LUNA 1000 RD GAS ...

Страница 19: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 19 LUNA 1000 RD GAS ...

Страница 20: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 20 1 2 3 4 5 6 7 8 9 5 6 7 9 1 2 4 3 8 10 11 12 10 11 12 LUNA 1300 RD GAS ...

Страница 21: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 21 LUNA 1300 RD GAS ...

Страница 22: ... or cracked the appliance must not be used until the window has been replaced Contact your M Design reseller 10 SAFETY ADVICE AND MAINTENANCE Have your furnace inspected once a year by a qualified technician Please observe the following points Closed appliances produce intense heat which means that all the surfaces of the exter nal walls metal door frames and windows become very hot once a certain...

Страница 23: ...ion 12 USING THE MANUAL CONTROL BLACK BOX On the user interface a potentiometer is connected This one will be used only when the remote control is broken DON T USE THE POTENTIOMETER SIMULTANIOUSLY WITH THE REMOTE CONTROL TO SET THE REQUIRED LOAD When no ignition with remote control set potentiometer knob off turn left Push once on the black push button You will hear the starpilot ignition Once you...

Страница 24: ... C 31 C 91 C 11 C 31 C 91 C 11 C 31 C 91 C 11 C 31 C 91 Inlet pressure mbar 25 20 30 37 50 28 30 Burner pressure mbar 24 2 19 3 29 4 36 2 36 2 28 4 Consumption m 3 h Injector burner 6x0 85 6x0 85 6x0 6 6x0 6 6x0 6 6x0 6 Injector startpilot 38 33A 38 33A 0 20P3 0 20P3 0 20P3 0 20P3 Rendement Nominal Charge KW Charge KW NOX emmission classe 5 5 5 5 5 5 Cat Rendement CE 1 1 2 2 2 2 LUNA 1000 RD GOLD ...

Страница 25: ...1 C 11 C 31 C 91 C 11 C 31 C 91 C 11 C 31 C 91 Inlet pressure mbar 25 20 30 37 50 28 30 Burner pressure mbar Consumption m 3 h Injector burner 6x1 1 6x1 1 6x0 65 6x0 65 6x0 65 6x0 65 Injector startpilot 38 33A 38 33A 0 20P3 0 20P3 0 20P3 0 20P3 Rendement Nominal Charge KW Charge KW NOX emmission classe 5 5 5 5 5 5 Cat Rendement CE 1 1 2 2 2 2 LUNA 1300 RD GOLD gas gaz 13 SPECIFICATION SHEET ...

Страница 26: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 26 LUNA 1000 RD GOLD gas connection gas on the back side ...

Страница 27: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 27 LUNA 1300 RD GOLD gas connection gas on the left side ...

Страница 28: ...cluding the buyer Heat cracks which normally occur in the mantel In cases where changes have been made to the furnace without our consent In cases where the buyer cannot show his her warranty card with the purchase invoice Li kewise where the guarantee and or the invoice show s signs of tampering or forgery crossed out date illegible modifications In the case you would like to make use of the manu...

Отзывы: