![Lynx PTG 5610 B/D Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/lynx/ptg-5610-b-d/ptg-5610-b-d_reference-manual_1953941037.webp)
P TG 5610 B/D Reference Manual. Rev 1.0
Page 37 of 53
Main Tab
The main tab contents are shown above, this GUI screen is shown when the device is
initially selected and shows module status and primary functions
Status Area
The top area shows the module status
Reference input
– if a reference is connected the detected format and standard is
displayed. Selection can be made for Rack Reference or Board Reference
Lock to Reference
– If annotated Green (as shown) this indicates P TG 5610 is
genlocked to the connected standard. The drop down menu allows the selection of the
genlock modes which are detailed below
Frequency Lock
– Basic Genlock (crosslock) mode, the P TG 5610 SD outputs
and the analog sync output is frequency locked to the connected reference. The
video delay is not valid in this mode (greyed out). The output sync formats are
qualified by the SDI standard selected and the Frequency Lock selection. Sync
Standards which are not supported are greyed out. The analog reference sync can
be delayed relative to the SDI output.
Timing Lock
– Timing lock (crosslock) mode will genlock to the connected analog
sync input and also provides for delay adjustment of the video and analog sync
outputs independently. One full frame of delay is possible for both the SDI output and
Sync outputs adjustable in lines / pixels or time. The subset of supported analog sync
outputs are reduced in timing lock mode, and any unsupported output formats will be
greyed out.