Lynx MiniModule S VD 3062 Скачать руководство пользователя страница 1

 

 
 
 

 

Series 3000 

© LYNX Technik AG 

Brunnenweg 3 

64331 Weiterstadt 

Germany 

 www.lynx-technik.com

 

Reference Manual 

S VD 3062 

SDI 6 > 2 Input Switch 

MiniModule

 

Version 1.4 

Содержание MiniModule S VD 3062

Страница 1: ...Series 3000 LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany www lynx technik com Reference Manual S VD 3062 SDI 6 2 Input Switch MiniModules Version 1 4...

Страница 2: ...tten permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Except...

Страница 3: ...ranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a...

Страница 4: ...s operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful in...

Страница 5: ...Control Panels 11 Power Connections 12 DC Power Connector 12 Installation 13 Mechanical 13 Stand Alone Operation 13 Multiple Units 14 Electrical Installation 15 Stand Alone Operation 15 Multiple Unit...

Страница 6: ...Reference Manual S VD 3062 Version1 4 Page 6 Auto Store 26 Specifications S VD3062 27 Available Options 28 Parts List 29 Service 29 Contact Information 30...

Страница 7: ...Mbit s 270Mbit s 360Mbit s and will transparently pass data from 10Mbits s to 620Mbits s in non reclocked mode A analog reference input allows clean switching for synchronous inputs Inputs can be swit...

Страница 8: ...he S VD 3062 MiniModule Video I O is made through standard BNC video connectors Module configuration is set via a small dip switch located behind a small access hole in the bottom of the module A conn...

Страница 9: ...Reference Manual S VD 3062 Version1 4 Page 9 Figure 2 Module Layout...

Страница 10: ...f high quality video cable for digital video connections to reduce the risk of interference or errors due to excessive cable attenuation Some guidelines for max cable length are shown below 250m 820 f...

Страница 11: ...t Select for OUT1or Input select f or Panel Version1 PIN A13 A8 Input Select forOUT2 PIN B7 Output 1 select for Panel Version 1 PIN B6 Output 2 select for Panel Version 1 PIN A7 Panel connect Low Pane...

Страница 12: ...dule has a captive power lead fitted to the module with a male 5 pin locking bayonet connector This connection provides DC power and also data connectivity to the module Connector wiring is shown belo...

Страница 13: ...3010 option is required to power each module Please refer to the R FR 3005 Reference Manual supplied with this option for more details b Single Use The MiniModule can be powered independently with the...

Страница 14: ...ack frame option Each module plugs into a connection bus which provides common power for all modules no R PS external power supplies are needed Remote control and status monitoring of all modules is p...

Страница 15: ...ction is solid and locked in place A strain relief is included within the module to prevent excessive strain on the connection Signal connections should be made with care please ensure connections are...

Страница 16: ...62 has an integrated micro controller which enables the module to be configured and controlled locally via the integral dip switch or from remote when using the optional R FR 3010 Rack Frame and contr...

Страница 17: ...a microcontroller and flash ram When this switch 1 is set to ON any configuration settings made on the module with the dip switches will automatically be written into flash ram and stored see Auto Sto...

Страница 18: ...les will switch automatically to the next active input OFF disables emergency switching Dip Switch 5 8 Used for address configuration for optional remote control panel on parallel or RS485 interface A...

Страница 19: ...th the module Tables below show pinout of Sub D 25 pin female connector as provided on the adapter Sub D 25 pin female PIN Function 1 6 Config Input select for OUT 1 or Input select for Panel Version...

Страница 20: ...6 OUT1 OUT2 390R 390R 390R 390R 390R 390R 390R 390R 5V 5V 5V 5V 5V 5V 5V 5V PIN12 25 5V PIN13 GND PIN20 PIN21 GND connect to GND for Panel detect unconnect for Panel Version 1 PIN1 PIN2 PIN3 PIN4 PIN5...

Страница 21: ...l Version 1 9 22 Not used 10 Not used 23 Not used 11 Not used 24 Not used 12 25 Power 5V 100mA max 13 Power GND Panel Version 2 25 pin Sub D Connector female this table shows relevant subset from tabl...

Страница 22: ...Reference Manual S VD 3062 Version1 4 Page 22 Panel Version 3 R CP 3062 D Sub 25 polig male...

Страница 23: ...config Output 1 select 8 config Output 2 select 14 19 config Select SVD3062 1 6 20 config not connect 21 config connect to GND 9 22 not used 10 not used 23 not used 11 not used 24 not used 12 25 Power...

Страница 24: ...l Panel with a serial interface Controller RS485 SVD3062 Loop Address Dip Switch Input Output 25 pin Sub D Connector female this table shows relevant subset from table page 18 PIN function 14 21 not u...

Страница 25: ...control is enabled If the LED 3 is ON Green local control is enabled if LED 3 is OFF local control is disabled Front Panel Alarm Indicator There is also a single alarm LED on the front side of the mo...

Страница 26: ...n the following continuous sequence 3 short flashes Pause 3 short flashes This uses the alarm LED located on the front of the module as well as any module edge LEDs green that may be used in the modul...

Страница 27: ...odes reclocked 6 2 for SMPTE 259M C signals non reclocked 6 2 for transparent digital signals up to 622Mbits Performance Cable Equalization Up to 200M using Belden 8281 270Mbit s Jitter 0 2 UI Control...

Страница 28: ...for single MiniModules Set for 5 MiniModules R FR 3005 This is a basic 19 inch rack mountable frame which can accommodate 10 MiniModules with power bricks R PS 1 or can be extended with the R FR 3010...

Страница 29: ...03 270 Service If you are experiencing problems or have questions concerning your S VD 3062 MiniModule please contact your local distributor for assistance We offer a fixed cost service exchange progr...

Страница 30: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik man...

Страница 31: ...Reference Manual S VD 3062 Version1 4 Page 31 This Page is intentionally left blank...

Страница 32: ...Reference Manual S VD 3062 Version1 4 Page 32 Notes...

Отзывы: