Series 5000
© LYNX Technik AG
Brunnenweg 3
D-64331 Weiterstadt
Germany
www.lynx-technik.com
Reference Manual
D VD 5010
Reclocking SDI Distribution Amplifier
CardModul
e
Version 1.0
Страница 1: ...Series 5000 LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany www lynx technik com Reference Manual D VD 5010 Reclocking SDI Distribution Amplifier CardModule Version 1 0...
Страница 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exce...
Страница 3: ...ranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a...
Страница 4: ...is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful i...
Страница 5: ...C 47 Part 15 4 Contents 5 Getting Started 7 Packaging 7 Product Description 7 Functional Diagram 8 Module Layout 8 Connections 10 Video Connections 10 Installation 11 Settings and Control 12 Alarm LED...
Страница 6: ...Reference Manual D VD 5010 Version 1 0 Page 6 This page is intentionally left blank...
Страница 7: ...primarily for broadcast and professional applications 8 reclocked outputs are provided with auto detection of standard digital video bit rates 143Mbit s 177Mbit s 270Mbit s 360Mbit s The D VD 5010 is...
Страница 8: ...the basic functional diagram for the D VD 5010 CardModule Figure 1 D VD 5010 Functional Diagram Module Layout Figure 2 shows the layout of the D VD 5010 CardModule and the rear connection panel Please...
Страница 9: ...Reference Manual D VD 5010 Version 1 0 Page 9 Figure 2 Module Layout Caution Use static precautions when handling the PCB Static discharge could result in serious damage to the module...
Страница 10: ...e of high quality video cable for digital video connections to reduce the risk of interference or errors due to excessive cable attenuation Some guidelines for max cable length are shown below 250m 82...
Страница 11: ...e located b Remove the blank connection panel from the rear of the rack if fitted c Install the rear connection panel using the screws supplied Do not tighten the screws fully d Slide the card module...
Страница 12: ...indicated via the Alarm LED on the front card edge or via the LYNX control system when using one of the optional controllers and control software Alarm LED Status Indicator The D VD 5010 module has a...
Страница 13: ...onal control system and software Once the specific module has been selected on the control system there is a locate button on the top of the GUI Locate Function in Control System When Locate is select...
Страница 14: ...p nom Return loss 15dB 270 Mbit s Connection BNC Performance Cable Equalization Up to 250m using Belden 8281 270Mbit s Jitter 0 2 UI Status Monitoring LED Signal presence Electrical Specifications Ope...
Страница 15: ...20 Rack controller for the R FR 5010 Card Frame R CT 5030 Master controller with TCP IP interface for the R FR 5010 Card Frame R CT 5010 Rack Bus Extension for the R FR 5010 Card Frame In combination...
Страница 16: ...stributor for assistance We offer a fixed cost service exchange program for defective Series 5000 CardModules out of Warranty Please contact your distributor or check our web site for details on this...
Страница 17: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik ma...
Страница 18: ...Reference Manual D VD 5010 Version 1 0 Page 18 Notes...