The module has a built in micro-controller with local 

controls, status and alarm indicators and well as 

internal flash ram for storing setups. Any operational 
parameters configured and stored into the module 

are recalled when powered up. Remote control 

and remote status monitoring is possible when used 
with the rack frame option and host controller. 

 

CardModules are installed in the series 5000 card 
frame (R FR 5010) that can accommodate up to 10 

CardModules. All modules are hot swappable and 

Options include full redundant power and a range 
of controller options.   

 

Содержание C DX 5024 C

Страница 1: ...Series 5000 LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany www lynx technik com Reference Manual C DX 5024 C SDI to Analog Audio Video Converter CardModule Version 2 0...

Страница 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exc...

Страница 3: ...rranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty...

Страница 4: ...is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful...

Страница 5: ...12 Audio Output Connections balanced 12 Installation 13 Link Settings 14 Balanced Unbalanced Audio 14 Settings and Control 14 Multi Function Switch 15 Using the Local Display Menus 16 Navigation 16 L...

Страница 6: ...Reference Manual C DX 5024 C Version 2 0 Page 6 This page is intentionally left blank...

Страница 7: ...og audio signals and in parallel as 2 x AES3 signals on a Sub D connection Three re clocked outputs of the input signal are provided to cascade several modules to de embed further audio groups if requ...

Страница 8: ...parameters configured and stored into the module are recalled when powered up Remote control and remote status monitoring is possible when used with the rack frame option and host controller CardModu...

Страница 9: ...Figure 1 below is the basic functional diagram for the C DX 5024 C CardModule Figure 1 C DX 5024 C Functional Diagram Module Layout Figure 2 shows the physical layout of the C DX 5024 C CardModule an...

Страница 10: ...Reference Manual C DX 5024 C Version 2 0 Page 10 Figure 2 Module Layout...

Страница 11: ...ndard 75 Ohm BNC connectors Connection is self explanatory We recommend the use of high quality video cable for digital video connections to reduce the risk of interference or errors due to excessive...

Страница 12: ...connector Figure 3 Audio output connection detail Pin Number Connection Pin Number Connection 1 Left 1 14 Left 1 2 GND Left 1 15 Right 1 3 Right 1 16 GND Right 1 4 Left 2 17 Left 2 5 GND Left 2 18 Rig...

Страница 13: ...be located b Remove the blank connection panel from the rear of the rack if fitted c Install the rear connection panel using the screws supplied Do not tighten the screws fully d Slide the card module...

Страница 14: ...he respective link is closed the pin of the audio output is set to ground Note It is not necessary to power down the frame to remove the card All Series 5000 Card Modules can be hot plugged unplugged...

Страница 15: ...Page 15 Multi Function Switch The CardModule is equipped with a multi function switch located on the front bottom edge of the card refer to figure 2 Figure 3 Switch Operation Up Down Enter Switch Ope...

Страница 16: ...s layered and navigation through the system is done using the UP and DOWN functions of the switch ENTER is used to move between menu levels and also enter a selection Navigation Local Adjustments Avai...

Страница 17: ...back one level when selected When an item is selected which has several setting possibilities the first value displayed will be the value currently stored in the system The order of the available set...

Страница 18: ...set Condition The C DX 5024 C is delivered preset for the following mode of operation Audio Group 1 selected Full Scale Level 15dBu analog Audio Video Output Component Test Signal Off If this is the m...

Страница 19: ...Reference Manual C DX 5024 C Version 2 0 Page 19...

Страница 20: ...Reference Manual C DX 5024 C Version 2 0 Page 20...

Страница 21: ...Reference Manual C DX 5024 C Version 2 0 Page 21...

Страница 22: ...Reference Manual C DX 5024 C Version 2 0 Page 22...

Страница 23: ...Reference Manual C DX 5024 C Version 2 0 Page 23...

Страница 24: ...indicates the status of the embedded audio in the selected audio group Alarm Indicator A Single alarm LED is provided which can be seen while the rack cover is fitted and provides a general alarm indi...

Страница 25: ...n selected on the control system there is a locate button on the top of the GUI Locate Function in Control System When Locate is selected the status indicator on the GUI and the module LED s will flas...

Страница 26: ...o noise 60 dB Impedance 75 Ohm BNC connector Analog Audio Outputs Signal 2 x Stereo analog audio balanced or unbalanced Impedance 50 Ohm Sub D 25 pin Connector Max Output level 24dBu into 10kOhms 0 dB...

Страница 27: ...T 5030 Master controller with TCP IP interface for the R FR 5010 Card Frame R CT 5010 Rack Bus Extension for the R FR 5010 Card Frame In combination with R CT 5020 5030 Parts List Due to the very dens...

Страница 28: ...istributor for assistance We offer a fixed cost service exchange program for defective Series 5000 CardModules out of Warranty Please contact your distributor or check our web site for details on this...

Страница 29: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik m...

Страница 30: ...Reference Manual C DX 5024 C Version 2 0 Page 30 This page is intentionally left blank...

Страница 31: ...Reference Manual C DX 5024 C Version 2 0 Page 31 Notes...

Отзывы: