29
See RoomPerfect™ troubleshooting if the measurement stops prematurely, and then retry the measurement.
Measuring Random Room Positions
When the focus position has been measured, the next step is to measure the acoustical properties of the
room. It is important to perform well spaced measurements to get a comprehensive image of the acoustical
properties of the room. See RoomPerfect™ troubleshooting if the measurement stops prematurely.
Keep taking measurements until RoomKnowledge reaches 90%.
Note: RoomKnowledge relates to the level of new information in the last measurement
–
if there is little new information, the system will translate it to the fact that it knows nearly
everything. When the RoomKnowledge does NOT increase after a measurement, it
means that the measurement gave a lot of new information to the calibration!
These are the rules of thumb when measuring the room:
•
The microphone should be in random and varying positions, heights, and orientations.
Point it up/down/sideways
– the more random positions the better.
•
The measurements should cover the primary listening area.
•
Do not take measurements behind plants, furniture, etc.
Side view of room
•
The microphone should not be closer than 0.5m/1.5ft from the floor, ceiling, and walls.
•
The microphone should be at least 1m/3ft from the front of the loudspeakers.
•
There should be at least 50cm/1.5ft between each measurement.
•
Do not take symmetrical measurements in the room.