background image

Flex Counter Standard 
Program version: Flexcounter 1.6 

 

 

Flex Counter Standard

Manual Version: UK 1.1 

 

 

 
 

Page 1 

 

 

 

Instruction manual 

Flex Counter Standard 

 

                 

 

 
 

 

 

System 

 

Lykketronic Flex Counter Standard 

Part number 

 

Serie number 

 

Installed by 

 

Installation date 

 

 

 
 
 

Содержание Flex Counter Standard

Страница 1: ...d Program version Flexcounter 1 6 Flex Counter Standard Manual Version UK 1 1 Page 1 Instruction manual Flex Counter Standard System Lykketronic Flex Counter Standard Part number Serie number Installed by Installation date ...

Страница 2: ... 2 4 1 3 UNIT COUNTER F 3 4 1 4 REVOLUTION COUNTER F 4 5 1 5 WORKING HOURS F 5 5 1 6 WRAP COUNTER F 6 5 2 OPERATION GUIDE 6 2 1 OVERVIEW 6 2 2 CHANGE OF ACTIVE FUNCTION 7 2 3 CHANGING AND RESETTING VALUES 7 2 4 TURNING THE FLEX COUNTER ON AND OFF STOP MODE 9 2 5 POWER SUPPLY 9 2 6 STORING DATA THE MEMORY OF THE FLEX COUNTER 9 3 INSTALLING THE SENSOR AND MAGNET 10 4 TECHNICAL DATA 10 5 FINAL REMARK...

Страница 3: ...ecommendable to mount the wheel sensor on a trailing wheel However on four wheel drives the rear wheel is recommended A distance equal to ten 10 wheel revolutions is driven This distance is measured and divided by ten The resulting factor is the wheel circumference The condition of the soil affects the accuracy of the circumference It is therefore an advantage to generate a circumference for hard ...

Страница 4: ...it is able to show on the display Therefore it may sometimes appear that counting errors are occurring even though that is not the case 1 3 Unit counter F 3 Before the unit counter can be used the counting factor must be set i e the factor by which the total number is increased when receiving a pulse signal This factor will usually be 1 but as illustrated in scheme The relationship between functio...

Страница 5: ...s Interval Display example 100 hours 54 23 100 hours 1275 The RPM timer may be reset according to the instructions given in paragraph Changing and resetting values 1 5 Working hours F 5 This function counts up the amount of time gone while the sensor is constantly short circuited If the Flex Counter is to be used as a stopwatch this can be done by short circuiting the sensor with the magnet or by ...

Страница 6: ...counter is reset When the required number of rotations has been reached and the computer does not receive any more pulse signals within a 10 seconds period The SET key is pressed while the display shows the wrap number PULS function 2 Operation guide 2 1 Overview Display In several functional modes the bottom bar will flash during work when the monitor receives sensor input SET key Start up For ac...

Страница 7: ...ROPA FERTIS 7 50 16 15 43 SD 3000 R15 14 20 Working width Machine model Working width PROSEM number of rows x Distance between elements C 00 01 99 99 m others depends to chassis type F 3 Unit counter Units cou R 0 001 9999 pcs Counting factor cou F C 0 001 9999 pcs F 4 Revolution Rpm r 0012 9999 rpm counter RPM hours R 00 00 9999 hours F 5 Working hours Working hours R 00 00 9999 hours F 6 Wrap co...

Страница 8: ...ue is correct SET 312 5 The third digit starts flashing F 0 9 315 5 Push repeatedly until the digit value is correct SET 315 5 The fourth digit starts flashing F 0 9 315 8 Push repeatedly until the digit value is correct SET 315 8 Press the key for app 2 sec leaving programming Not all factors contain a comma just as it is not always possible to change its position In those cases please disregard ...

Страница 9: ... computer then checks the power level if this is to low the display shows bL If the Flex Counter is then automatically turned off the batteries must be changed If the power supply from the batteries are to low the computer will occasionally flash the bL message during use The batteries must then to be changed as counting errors may then occur If display problems occur after battery replacement wai...

Страница 10: ...mperature limits The Flex Counter is fully operational within 10o C 70o C This does not necessarily apply for all types of batteries please check with your local battery dealer Pulse signals from the sensor Max 167 pulse signals per second Min pulse time 0 6 ms the magnet must activate the sensor for 1 10 of the time at 9999 rpm Area counter Max 0 100 Ha per second 360 Ha per hour Unit counter Max...

Страница 11: ...escribed in this instruction manual Any other use of the controller monitor can potentially involve significant risk and disclaim the supplier of this controller monitor for any responsibilities liabilities Please note that Lykketronic A S solely is responsible for the electronic controller monitor and not for the complete function of the machine including the safety aspects of the entire machine ...

Страница 12: ...Notes Page 12 ...

Страница 13: ...Notes Page 13 ...