Страница 1: ...Intelligent Alarm System User Manual Ver 1202 2012 02 14 ...

Страница 2: ...alarm dealing and controlling remotely conveniently and flexible and solves the limitation of wired data transmission in telephone and wired network Perfect structure convenient installation easy operation with wireless remote controllers are designed for the idea of people oriented which will make you feel easy and comfortable while using this intelligent alarm system People is center technology ...

Страница 3: ... 3 Programming phone numbers for voice calling alarm 9 5 4 Modifying the password of alarm host 9 5 5 Modifying alarm host ID 9 5 6 Whether send SMS or not when arm disarm 10 5 7 Exiting setting status 10 6 Programming by SMS command 10 6 1 Programming 3 mobile phone numbers for SMS alarm 10 6 2 Programming 3 phone numbers for voice calling alarm 11 6 3 Deleting alarm phone numbers 11 6 4 Modifyin...

Страница 4: ...arm 13 6 12 Cancel independent arm 13 7 Programming by phone keypad remotely 14 8 Operating steps 15 8 1 Arm disarm by remote controller 15 8 2 Emergency alarm 15 8 3 AC power failure alarm 15 8 4 Handling alarm 16 8 5 Arm disarm and listen in remotely 16 9 Installation and operation cautions 17 10 Encode method 18 ...

Страница 5: ...mote control the host such as arm disarm etc 1 1 Main functions l Whether send SMS or not when arm disarm l Arm disarm remotely by phone keypad l Automatically send SMS to 3 preset phone numbers while alarming l Automatically call 3 preset phone numbers and start on site listen in while alarming l Real time report the alarm zone remotely by SMS and voice reminding l With user friendly voice remind...

Страница 6: ...requency 900 1800 850 1900MHz 3 Alarm response time 8s GSM signal in normal 4 Power requirements AC 220V 50Hz 60Hz Working consumption 0 6W Backup battery DC7 4V 850MA Backup battery working hours 10 hours 5 Working condition temperature 20 60 humidity 95 non condensation 6 Size 150mm L 100mm W 16mm H 7 Record time 10s ...

Страница 7: ...sensor or remote controller the LED will be on otherwise is off 3 RUN LED indicator blinking every 2s when the GSM signal is normal when the GSM signal is failure it blinks every 1s 4 ALARM LED indicator When there is an alarm or entering into setting status it will be on when there is no alarm or escaping the setting status it will be off ...

Страница 8: ... arm status the LED is on 6 ARM LED indicator After system armed it will be on it will be off when disarm 7 Power LED indicator External AC power is connected the LED is on external AC power is failure the LED is off Shown as above 1 Fixing hole Use for fixing the alarm host ...

Страница 9: ...2 Power switch Switch to right is on Switch to left is off Shown as above 1 SIM card socket 2 Learning button 3 Recording button 4 Setting button 5 Siren socket 6 Power supply socket ...

Страница 10: ...ou should prepare a SIM card before the installation If you use a new SIM card you should check the new SIM card carefully whether it can send SMS and make calls normally or not Notes Please turn off the power before insert SIM card and make sure the direction is correct 3 2 The connection of wired detectors and speaker The alarm host is configured with 2 wired alarm zones and ...

Страница 11: ...crewdriver you will see 6 wires inside the host Shown as below Of which Red wire anode of the intercom speaker black wire the cathode of the intercom speaker Both yellow wires are for wired zone 1 Both green wires are for wired zone 2 2 Draw out these wires of wired detectors intercom speakers from the back of the alarm host shown as following ...

Страница 12: ...st gets into initialization gets into the status of GSM network searching after that it will make two di di beep sounds for confirmation then the alarm system get into normally working At this moment the Alarm indicator light and arm indicator light will be off the RUN indicator light will blink 2s time Notes If the RUN indicator light keeps brightening or keeps light off it means that the alarm h...

Страница 13: ... host by wireless control keypad 5 1 Get into setting status During the host s running status press set button it will make two di di beep sounds at the meanwhile the ALARM LED is on It means the host enters into the setting status Then you can start to program the alarm numbers Note When setting by the keypad every time you press the button you will hear di sounds for confirmation if there s no v...

Страница 14: ...id not set the first sms alarm number you will be unable to know whether all of the contents of the setting are right or not 5 3 Programming phone numbers for voice calling alarm In setting status input Serial number phone number Example Program phone number 13688888888 as the first voice calling number Input 413688888888 then you will hear di di sounds for confirmation Repeat the process to set t...

Страница 15: ...23456 after setting successfully you will here two di di confirmation sounds 5 6 Whether send SMS or not when arm disarm When operate the host by remote controller if you want to let host send arm disarm SMS to mobile phone please follow up the steps as below In setting status input 9 on wireless keyboard then you will hear di di sound for confirmation Repeat the operation you can cancel this func...

Страница 16: ...ully setting the SMS alarm mobile number Note The serial number shows alarm sequence must be 1 2 3 6 2 Programming 3 phone numbers for voice calling alarm Input SMS 4 digits password DD serial number call alarm phone number Example The host s password is 1234 set 01088888888 as the first call alarm phone number Send SMS 1234DD401088888888 Note The serial number shows alarm sequence must be 4 5 6 6...

Страница 17: ...isarm by SMS 4 digits password A2 Example The host s password is 1234 If you want to set the host in arm mode remotely control then you may send one SMS 1234A1 6 6 Change Zone s name Input SMS 4 digits password DM zone s code 2 digits New zone s name Return SMS New zone s name Example The host s password is 1234 If you want to change zone 06 s name into Our bedroom PIR Alarm Send SMS 1234DM06Our b...

Страница 18: ... host s external power status 6 10 4 Languages Switchover Input SMS 4 digits password LG series number Notes Series number stands for 1 2 3 4 of which 1 stands for English 2 stands for Chinese 3 stands for Russian 4 stands for Spanish After setting successfully you will get 3 SMS reply for switching to related language 6 11 Independent arm When the independent zone in independent arm status only S...

Страница 19: ...as been in status of independent zone 6 12 Cancel independent arm When the independent zone in the independent arm status only SMS command can control the independent zone doesn t accept any other modes control So we can use SMS to cancel the independent arm SMS input 4 digits password AD Zone series number Notes The zone series number stands for 10 zones from zone01 to zone 10 you can cancel mult...

Страница 20: ... will make click sounds If not this means your operation is unsuccessful you should press it again You can press to cancel the numbers which you have already inputted before press 1 Program mobile phone numbers for SMS alarm 2 Program mobile phone or telephone numbers for alarm call 3 Modify password of the host 4 Modify new ID of the host 5 Set alarm host whether reply arm or disarm SMS or not 6 ...

Страница 21: ...cy alarm 8 3 External power failure alarm When the system checks out that there s something wrong with the external power or the external power is off for more than 2 seconds it will enter into alarm status immediately At the same time the system will automatically dial the pre defined phone numbers cycled for three times and send the SMS of External power failed When the power supply restored to ...

Страница 22: ...gered the host will broadcast the zone numbers to you 8 5 Remote arm disarm and monitor at site You can use any telephone or mobile phone to dial the phone number of the host the host will automatically get through after 15 seconds detecting and remind you of inputting password with voice If the entered password is wrong for 3 times the host will hand up the phone automatically if the entering pas...

Страница 23: ... good heat dissipation 5 Don t install the system close to the objects which generate strong interference such as TV set and computer 6 Check all the detectors and their battery in time and change them when power is low 7 Inspect the GSM alarm system timely 8 This product is designed for the indoor use rather than outdoor use 10 The method for encoding wireless detectors remote controllers Name Wi...

Страница 24: ...tact 3 Beam detectors 4 Smoke detecotrs Zone 01 1 0 1 0 Zone 02 0 1 1 0 Zone 03 1 1 1 0 Zone 04 1 0 0 1 Zone 05 0 1 0 1 Zone 06 1 1 0 1 Zone 07 0 0 1 1 Zone 08 1 0 1 1 Zone 09 0 1 1 1 Zone 10 1 1 1 1 Panic button 0 0 1 0 Fire zone 1 1 0 0 Remark A0 A7 D0 D3 use jumpers or tin soldering for connecting the pins Connect N H stands for 1 Connect N L stands for O no connection stands for 2 ...