LX MOP2
Means of propulsion sensor 2
Installation manual
Version 1.1
LXNAV d.o.o.
• Kidričeva 24
, 3000 Celje, Slovenia
• tel +386
592 33 400
•
fax +386 599 33 522
[email protected]
www.lxnav.com
Страница 1: ...LX MOP2 Means of propulsion sensor 2 Installation manual Version 1 1 LXNAV d o o Kidričeva 24 3000 Celje Slovenia tel 386 592 33 400 fax 386 599 33 522 info lxnav com www lxnav com ...
Страница 2: ...LX MOP2 March 2018 Page 2 of 10 1 Important Notices 3 1 1 Limited Warranty 3 2 Packing list 4 3 Fitting MOP2 5 4 Functional test 7 5 Analysing MOP2 record 8 6 Technical 9 7 Revision history 10 1 ...
Страница 3: ...tions or repairs THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED OR STATUTORY INCLUDING ANY LIABILITY ARISING UNDER ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE STATUTORY OR OTHERWISE THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS WHICH MAY VARY FROM STATE TO STATE IN NO EVENT SHALL LXNAV BE LIABLE FOR ANY IN...
Страница 4: ...LX MOP2 March 2018 Page 4 of 10 2 Packing list MOP2 BOX with attached Hall current sensor 3 5m RS485 extension cable Male Female Installation manual ...
Страница 5: ...e screw holding the hall current sensor frame closed and then open it Place the positive lead cable from the battery through the open hall current sensor refer to Figure 3 for positive current flow close the frame and screw it back If the cable going through the sensor is not fixed entirely too small diameter we recommend padding the section of the cable that goes through the sensor before final f...
Страница 6: ...LX MOP2 March 2018 Page 6 of 10 Figure 3 Hall sensor positive current flow direction ...
Страница 7: ... LXxxxx device and a FCU unit 2 On the LXxxxx device go to Setup Password menu 3 Insert password 09978 4 Add power on FES 5 Check Current on LX9000 and FCU unit it should be equal ENGINE NOISE LEVEL option On the LXxxxx go to SETUP HARDWARE ENGINE 1 Add power on FES 2 Check MOP level percentage bar it should be equal to FCU unit 100 100 Amp current ...
Страница 8: ...LX MOP2 March 2018 Page 8 of 10 5 Analysing MOP2 record Mop record is stored in IGC file as additional column called MOP Mop values are normally moving between 0 and 999 ...
Страница 9: ...LX MOP2 March 2018 Page 9 of 10 6 Technical Property Value Note MOP2 Current consumption 70Ma At 12V MOP2 Input voltage range 9 18V Hall current range 300A ...
Страница 10: ...LX MOP2 March 2018 Page 10 of 10 7 Revision history March 2018 Complete revision of this manual ...