Rev #
23
Version 7.10
December
2019
Page
36
of 224
If a new pilot is entered, upon exiting the dialogue the message
“Do you want to create new
profile with this pilot?”
wi
ll
appear. Answer
YES
if you want to quickly add
a new profile.
For more information about profiles see Chapter
The user can also enable options
to
log other aircraft data
(FLARM
data)
and flap positi
on.
5.1.3
Vario Parameters*
This option is used to set
the vario parameters.
Following
parameters are set:
Vario needle filter
sets a time constant of the vario needle. The value can be adjusted
between 0.1 and 5
s with step 1.0 s or 0.1
s. Default value is 1.5
s.
Vario sound filter
sets a time constant of
the
vario sound. The value can be adjusted
between 0.1 and 5
s with step 1.0 s or 0.1
s. Default value is 1.5
s.
Vario range
sets full scale range of the vario (2.5
m/s, 5
m/s or 10
m/s). Default value i
s
5
m/s (10
kts).
SC tab
defines the width of the
audio dead band in speed to fly mode. Default value is
±1 m/s.
Integrator time
defines the integration period for the average vario in seconds. The
default is 20 seconds.
Auto SC
defines the conditions when the instrument is switched automatically betwe
en
vario and speed command.
•
OFF
: Switching is exclusively by an external switch connected to the vario unit.