background image

Vehicle 12-80VDC Power Connection

1. Vehicle Electrical System

2. 2 Amp Slow Blow Fuse

3. DC +

4. DC -

5. Vehicle Chassis

6. Red

7. Black

8. White

Note: Correct electrical polarity is required for safe and proper installation. See the following figure titled “Vehicle
Connection Wiring Color Codes” for additional wire color-coding specifics.

How To: Connect Vehicle 12-80 VDC Connection

1. The VX3X must be turned off and the power cable must be UNPLUGGED from the VX3X.

2.  While observing the fuse requirements specified above, connect the power cable as close as possible to the actual bat-

tery terminals of the vehicle. When available, always connect to unswitched terminals in vehicle fuse panel, after pro-
viding proper fusing.

ATTENTION:For uninterrupted power, electrical supply connections should not be made at any point after
the ignition switch of the vehicle.

3. Route the power cable the shortest way possible. The cable is rated for a maximum temperature of 75°C (167°F). When

routing this cable it should be protected from physical damage and from surfaces that might exceed this temperature.
Do not expose the cable to chemicals or oil that may cause the wiring insulation to deteriorate.

Note: If the vehicle is equipped with a panel containing Silicon Controller Rectifiers (SCR’s), avoid routing the
power cable in close proximity to these devices.

Always route the cable so that it does not interfere with safe operation and maintenance of the vehicle.
Use proper electrical and mechanical fastening means for terminating the cable. Properly sized “crimp” type electrical
terminals are an accepted method of termination. Please select electrical connectors sized for use with 22AWG (1mm

2

)

conductors.
Wiring color codes for LXE supplied DC input power cabling:

E-EQ-VX3XOGWW-G-ARC [ 11  ] VX3X User Guide

Содержание VX3X

Страница 1: ...s obsolete This electronic guide has been made available as a courtesy to our customers Contact your LXE representative for replacement and assistance E EQ VX3XOGWW G ARC 2010 Copyright by LXE Inc An...

Страница 2: ...of Summit Data Communications Inc The Cisco Square Bridge logo is a trademark of Cisco Systems Inc Aironet Cisco and Cisco Systems are registered trademarks of Cisco Systems Inc and or its affiliates...

Страница 3: ...Power Connection 10 Connect Power Cable 12 Connecting the Headset Cable 13 Adjust Headset Microphone and Secure Cable 14 Connecting a Tethered Scanner 15 Attach Stylus Tether and Sleeve 15 Set Date an...

Страница 4: ...onnection Indicator 22 Reboot 23 Warm Boot 23 Cold Boot 23 Troubleshooting 23 Regulatory Notices and Safety Information 24 Class A Digital Device 24 RF Notices 25 RF Safety Notice 25 Lithium Battery S...

Страница 5: ...nect a tethered scanner to the VX3X l Place the VX3X in a powered dock or cradle Hardware Setup 1 Connect accessories 2 Connect cables 3 Connect power cable 4 Secure all cables to the VX3X with the St...

Страница 6: ...s Components Front 1 Endcap 2 Display 3 Programmable Key 4 Beeper 5 On Off Button 6 2nd LED 7 Alt LED 8 Ctrl LED 9 Shift LED 10 Caps LED 11 Status LED 12 Programmable Key E EQ VX3XOGWW G ARC 2 VX3X Us...

Страница 7: ...Back Back 1 RAM Ball 2 Power Connector 3 Strain Relief Clamp E EQ VX3XOGWW G ARC 3 VX3X User Guide...

Страница 8: ...Right Port 4 Audio Jack or External Antenna Connector Audio Jack shown Endcap Options Left Port Right Port COM3 RS 232 USB Client USB C COM3 RS 232 COM1 RS 232 USB Host USB H COM1 RS 232 USB Host USB...

Страница 9: ...e mouse pointer then left clicking icons on a desktop computer screen Using the stylus to tap icons on the touchscreen is the basic action that can l Open applications l Choose menu commands l Select...

Страница 10: ...T The next keypress is an ALT keypress Amber when on and unlit when off CTRL The next keypress is a CTRL keypress Amber when on and unlit when off SHFT The next letter is the uppercase letter on alpha...

Страница 11: ...ter 2 on the cable provides a USB Host connection Connect Cable USB Client Prerequisite An endcap with a USB Client port labeled USB C A commercially available standard USB cable with a type A plug on...

Страница 12: ...the serial COM port on the VX3X endcap 2 Turn the thumbscrews in a clockwise direction Do not over tighten 3 Use a strain relief clamp to secure the cable to the VX3X 4 Connect the other cable end to...

Страница 13: ...rated 12 80 VDC minimum 15W75W The external power supply may be connected to either a 120V 60Hz supply or outside North America to a 230V 50Hz supply using the appropriate detachable cordset In all ca...

Страница 14: ...ting rating fuse If the supply connection is made directly to the battery the fuse should be installed in the positive lead within 5 inches of the battery positive terminal Note For North America a UL...

Страница 15: ...made at any point after the ignition switch of the vehicle 3 Route the power cable the shortest way possible The cable is rated for a maximum temperature of 75 C 167 F When routing this cable it shoul...

Страница 16: ...e to the VX3X Connect Power Cable 1 Connect the power cable to vehicle power See Vehicle 12 80VDC Power Connection 2 The plug and receptacle are keyed and care must be used when connecting the cables...

Страница 17: ...rophone Connect the VX3X voice cable I O connector to the I O port on the VX3X The VX3X internal microphone and speaker are automatically disabled Slide the voice cable ends together until they click...

Страница 18: ...about two finger widths from your mouth Make sure the microphone is pointed at your mouth Note the small Talk label near the mouthpiece Make sure the Talk label is in front of your mouth The micropho...

Страница 19: ...t selected The COM port that accepts the scanner data can be configured for data rate parity stop bits and data bits Attach Stylus Tether and Sleeve The stylus kit includes the stylus tether and sleev...

Страница 20: ...rches the Internet for a time server A connection to the Internet is required for this option Autolaunch Time Sync Start Settings Control Panel VX3X Options Communication tab By default TimeSync does...

Страница 21: ...he CAPS key to type all capital letters l Tap the key to access symbols Some applications do not automatically display the Input Panel In this case do the following to use the Input Panel Input Panel...

Страница 22: ...ume until the speaker volume is satisfactory Press the Enter key to exit this mode The LED for the 2nd key blinks until the special editing mode set audio speaker volume is complete Volume control usi...

Страница 23: ...tab in the Power control panel When the backlight timer expires the display backlight is dimmed not turned off When both checkboxes are unchecked the backlight never turns off or dims Default values...

Страница 24: ...mber Telnet Port of the host system to properly set up your host session 1 Make sure the mobile client network settings are configured and functional If you are connecting over wireless LAN 802 11x ma...

Страница 25: ...t application in the AppLock configuration is moved to the foreground and the previous application moves to the background The previous application continues to run in the background VX3X key presses...

Страница 26: ...targeted Bluetooth device during the discovery and pairing process If the devices are in Suspend tap the power key to wake the VX3X Using the correct procedure wake the targeted Bluetooth device if ne...

Страница 27: ...ype COLDBOOT EXE or COLDBOOT This command is not case sensitive2 Tap the OK button Note Because of the extreme nature of cold boot LXE recommends using this command only as an emergency or when instru...

Страница 28: ...ons Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause...

Страница 29: ...ories not provided by LXE should not be used with this device This device must not be co located or operating in conjunction with any other antenna or transmitter R TTE Directive Requirements Applies...

Страница 30: ...tteria venga sostituita in maniera scorretta Sostituire solo con lo stesso tipo o equivalente consigliato per il fabbricante IT Aten o Cont m pilha de l tio H perigo de explos o no caso de uma substit...

Страница 31: ...lenta da 2 A nel conduttore positivo a meno di 5 in 12 7 cm dal terminale positivo della batteria IT Tilkople str mforsyningen til kj ret yet Hvis str mforsyningen koples direkte til batteriet skal d...

Страница 32: ...cting Cables 7 Connecting the Headset Cable 13 Connecting Vehicle Power 10 Connection Indicators 22 D Date Time TimeZone 16 Daylight Savings location 16 G Grab Time Utility 16 H Hardware Setup 1 Heads...

Страница 33: ...connectors for use with 22AWG conductors11 Software Setup 1 Stylus how to use 5 Switchpad 21 Sync button 16 Synchronize with a Local Time Server 16 T Touchscreen and the stylus 5 Touchscreen protecti...