Features
3
E-EQ-NEMARG-F
NEMA Type 4 Enclosure Reference Guide
Security
The front lid of the Enclosure is permanently attached and is secured in the closed position with
seven (7) locking tabs and screws, ensuring the watertight seal of the unit. For additional security,
the latch can be secured with a standard user-supplied padlock.
Mounting
The Enclosure is designed for vertical wall mounting. If the Enclosure will not be mounted
directly on the wall, LXE recommends mounting the Enclosure on ¾ inch (1.90 cm) plywood
mounting boards measuring 30” x 40” (76.2 cm x 101.6 cm).
Using a mounting board allows the Enclosure to attached to a ceiling truss or support column
using beam clamps, “U” bolts, or other secure methods. To maintain the NEMA Type 4 rating,
the Enclosure must be mounted vertically.
If you are uncertain as to the quality of your facility’s electric power (i.e. surges, spikes, lightning
strikes, brown outs, noise, etc.), LXE recommends that you install an Uninterruptible Power
Supply (UPS) for each unit. Select a UPS with approximately 250VA - 500VA capacities.
Note:
Optional lightning suppression for AC power is available on the Enclosure.
Enclosed Devices
The Enclosure is designed to house Access Points and bridges. LXE offers mounting kits for the
following devices
•
LXE 6730 (Cisco Aironet 1200 802.11b Access Point)
•
LXE 6740 (Cisco Aironet 1200 802.11g Access Point)
•
LXE 6723 (Cisco Aironet 350 Wireless Bridge)
•
LXE 6720 (Cisco Aironet 350 Access Point)
•
LXE 6520 (Orinoco 1000 Access Point)
•
LXE 6540 (Proxim Orinoco AP600 Access Point)
•
LXE 6543 (Proxim MP.11 Wireless Bridge)
Note:
The LXE 6740 uses the same mounting kit as the LXE 6730. Please refer to
the appropriate LXE 6730 instruction sheet to install an LXE 6740.
Kits are available to mount these devices alone or in combination. Please contact your LXE
representative for available mounting combinations. Some of the network products (AP’s and
Bridges) mentioned in this document are obsolete. LXE continues to offers kits to mount these
devises as a service to our customers.
Note:
The above devices have been tested and approved by LXE. Other Access Points and
Bridges may be used in the Enclosure, but have not been tested by LXE. For information
on obsolete equipment used in the NEMA enclosure, please refer to the archive section of
the LXE ServicePass website.
Содержание Nema 4
Страница 4: ......
Страница 8: ...iv Table of Contents NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 20: ...12 Accessories NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 42: ...34 Installation Procedure LXE Model 6520 AP non RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 106: ...98 Installation Procedure LXE Models 6723 Bridge 6730 AP non RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 118: ...110 Installation Procedure LXE Models 6723 Bridge 6720 AP non RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 134: ...126 Installation Procedure LXE Model 6520 AP RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 198: ...190 Installation Procedure LXE Models 6723 Bridge 6730 AP RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 210: ...202 Installation Procedure LXE Models 6723 Bridge 6720 AP RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 216: ...208 Installation Procedure Lightning Suppression Accessories RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 220: ...212 Index NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...