SW-P
VR501
RF-SW
TP502
WF2
C-PB
TP301
WF3
CTL
TP501
V-OUT
J23
WF1
S-INH
TP507
Main CBA Top View
NOTE :
The voltage for parts in hot circuit is measured
using hot GND as a common terminal.
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT , AN ISOLATION TRANSFORMER MUST BE USED.
ALSO , IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY , WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
CIRCUIT , A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
CAUTION !
Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
Sensor CBA Top View
BHF300F01011A
BHF300F01011B
1-8-17
1-8-18
BHG470F01014A
Содержание LUX214VR
Страница 23: ...1 8 3 1 8 4 HG410SCM1 Main 1 6 Schematic Diagram...
Страница 24: ...Main 2 6 Sensor Schematic Diagrams 1 8 5 1 8 6 HG410SCM2...
Страница 25: ...Main 3 6 Schematic Diagram 1 8 7 1 8 8 HG410SCM3...
Страница 26: ...Main 4 6 Jack Sub Jack Schematic Diagrams 1 8 9 1 8 10 HG410SCM4...
Страница 28: ...1 8 13 1 8 14 HG410SCM6 Main 6 6 Schematic Diagram...
Страница 29: ...1 8 15 1 8 16 HG410SCAFV AFV Schematic Diagram...
Страница 32: ...1 8 21 1 8 22 Jack CBA Top View Jack CBA Bottom View BHG470F01014C...
Страница 39: ...1 13 1 HG410FEX EXPLODED VIEWS Front Panel A1X...
Страница 75: ...LUX214VR HG410ED 2004 06 03...