Luxibel B EXPO350M Скачать руководство пользователя страница 7

 

 

 

Maintenance

 

 

  

Operation only allowed to qualified person, damages due to unprofessional operation or 

remove of any parts inside will not be considered in warranty service. There are no 
serviceable parts inside the device or package, service only leaves to authorized dealers.  
  

Never allow the optical components contact with oil, fat or any other liquid.  

  

A regular clearance of the device is needed for long-term usage, this is very helpful to 

maintain the lifetime and brightness need to use a soft and lint-free cloth to clean the optical 
system, fan and air flowing tunnel.  
  

Trouble shooting 

 

  

Problems 

 

Possible reasons 

 

Solutions 

 

Device not 
power up  

Powercon or power cable 
damaged  
Faulty power supply  

Change a good power cable to try  
  
Replace new power supply  

LED off  

Temperature protection  
Fan not working  
Faulty LED  
Dimmer and strobe set at 0  
  
Faulty power supply  

Check the temperature from menu  
Check the fan speed info from menu  
Replace new LED  
Set dimmer channel at 255 and strobe 
channel at 0~5  
Replace new power supply  

Device not  
response to  
DMX  

Faulty communication IC   
  
Faulty display PCB  
Wrong DMX addressing  
Faulty DMX cable  

Replace the IC with back-up one in the 
display PCB  
Replace new display PCB  
Check the address and setting  
Change to a good DMX cable  

Fans not 
working 
properly 
 

Head cover is pushing up to 
the fan and hereby blocking 
movement 

Check if it’s possible to unblock the fan 
 
Replace head cover 

Light goes out 

One or more fans are not 
working properly 

Set Fan mode to high, now check in 
information the fan speed

 

this cannot be close to 0, if this is the case: 
 
Check if the fan is blocked 
Check the fan cable connections 
 

  

Replacement of the fuse

 

 

  

Step 1: Unplug power cable from main power  
Step 2: Unscrew the fuse holder out of the housing with a screwdriver  
Step 3: Remove the broken fuse and replace with an exact same type of new fuse  
Step 4: Insert the fuse holder back to the housing and screw tight and reconnect power  

  

  

Содержание B EXPO350M

Страница 1: ...1...

Страница 2: ...2 User Manual Table of contents Product introduction 3 Safety Notes 4 Maintenance 7 Installation 8 Control Menu 10 DMX Mode 12 Technical Specifications 14...

Страница 3: ...make sure that the packaging is in good condition and that following items will be found in the box B EXPO350M fixture 3m DMX cable 1 5m power cable with powercon Safety chain Description of the B EX...

Страница 4: ...to avoid danger Lenses glasses or UV filters must be replaced if they are visually damaged or their effectiveness is impaired e g by broken glass or by deep scratches Ensure that wires never come in...

Страница 5: ...away from children and unskilled people There are no wear parts in the device Maintenance and service must be performed only by an authorized service partner Before operate this unit please carefully...

Страница 6: ...ures in photosensitive persons or persons with epilepsy Especially at beam effect extreme caution and observance of these safety instructions is mandatory Don t put or install the device on a surface...

Страница 7: ...temperature from menu Check the fan speed info from menu Replace new LED Set dimmer channel at 255 and strobe channel at 0 5 Replace new power supply Device not response to DMX Faulty communication I...

Страница 8: ...of used material and the fixture itself Never try to do the installation by yourself if you are not qualified instead you have to instruct a skilled installer Inappropriate installations can cause inj...

Страница 9: ...ways like left picture The mounting place must be sufficient stable and be able to support a weight of 10 times of the unit s weight When the fixture is hanged always additionally secure the device wi...

Страница 10: ...5F Dimmer 0 255 dimmer fine zoom tilt pan strobe Information Lamp Temp XXXC FAN Speed FAN1 XXXR FAN2 XXXR FAN3 XXXR soft version V1 0 Settings fixture Set Temper C F Fahrenheit Celsius Celsius Fans Mo...

Страница 11: ...11 Freq rate 600Hz 1200Hz 2000Hz 2400Hz 4000Hz Reload Def Basic Reload ON OFF OFF Password XXX All Reload ON OFF OFF...

Страница 12: ...e mode at standard 18 channels mode and there are several models need to be independently controlled we just simply address first fixture at 1 and second fixture at 21 third one at 41 etc If the devic...

Страница 13: ...sistance please just contact authorized dealers Hibernation the device will enter sleeping mode if activated after a period of disconnecting DMX signal to save the power consumption and will return im...

Страница 14: ...5 4 lbs Mounting options Hanging 3x M12 hole Standing n a 2nd suspension safety wire 1x eye in back of unit to pass carabiner Control Menu control TFT display with 4 buttons Control DMX512 manual In L...

Страница 15: ...B Expo350MCW Light output 15 Lux 5m 5400 lux Lux 10m 1480 lux Lux 15m 834 lux Light output 45 Lux 5m 975 lux Lux 10m 369 lux Lux 15m 202 lux Electrical Fixture rated power 320W LED engine 350W 3000 K...

Страница 16: ...16 Contact Luxibel Bedrijvenpark De Veert 13 004 2830 Willebroek Belgium 32 3 860 76 50 info luxibel com www luxibel com...

Отзывы: