2
Johnson Controls Unitary Products
402697-LTG-B-1008
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
LEFT SIDE
RIGHT SIDE
.5”
.5”
RETURN END
B
24.25”
30.25”
28.5”
Gas Pipe
Entry
Thermostat
Wiring
FRONT
14”
1”
1.5”
23”
SUPPLY END
C
24.38”
20”
.5”
B
Gas Pipe
Entry
Thermostat
Wiring
33”
A
.5”
Electrical
Entry
Electrical
Entry
Vent Connection
Outlet
Vent
Connection
Outlet
4” Diameter
Outlet
Vent Connection
Cabinet and Duct Dimensions
Models
Nominal
CFM (m
3
/min)
Cabinet
Size
Cabinet Dimensions (Inches)
Approximate
Operating Weights
A
B
C
Lbs
LM(8,L)M060A12MP11
1200
A
14 1/2
13 1/4
10.3
94
LM(8,L)M080B12MP11
1200
B
17 1/2
16 1/4
11.8
103
LM(8,L)M080C16MP11
1600
C
21
19 3/4
13.6
114
LM(8,L)M100C16MP11
1600
C
21
19 3/4
13.6
118
LM(8,L)M100C20MP11
2000
C
21
19 3/4
13.6
122
LM(8,L)M120C20MP11
2000
C
21
19 3/4
15.8
129
Ratings & Physical / Electrical Data
Models
Input
Max/Min
Output
Max/Min
AFUE
Nominal
Airflow
Total
Unit
Amps
Air Temp.
Rise Max
Input
Air Temp.
Rise Min
Input
MBH
MBH
CFM
°F
°F
LM(8,L)M060A12MP11
60/30
47/24
80.0
1200
7.0
35-65
20-50
LM(8,L)M080B12MP11
80/40
62/32
80.0
1200
7.5
40-70
20-50
LM(8,L)M080C16MP11
80/40
62/32
80.0
1600
10.0
40-70
20-50
LM(8,L)M100C16MP11
100/50
78/40
80.0
1600
10.0
40-70
20-50
LM(8,L)M100C20MP11
100/50
78/40
80.0
2000
17.0
35-65
20-50
LM(8,L)M120C20MP11
120/60
95/48
80.0
2000
17.0
45-75
25-55
Models
Max.
Outlet
Air Temp
Blower
Blower
Wheel
size
Max
Over-Current
Protect
Min. wire Size
(awg) @ 75 ft
one way
°F
HP
Amps
LM(8,L)M060A12MP11
165
1/3
4.8
11 x 8
15
14
LM(8,L)M080B12MP11
170
1/3
4.8
11 x 8
15
14
LM(8,L)M080C16MP11
170
1/2
7.5
11 x 10
15
14
LM(8,L)M100C16MP11
170
1/2
7.5
11 x 10
15
14
LM(8,L)M100C20MP11
165
1
14.5
11 x 11
20
12
LM(8,L)M120C20MP11
175
1
14.5
11 x 11
20
12