background image

 

 

 

Lumishade 

Product Manual

 

 

 

 

 

 

 

 

 

Содержание Lumishade

Страница 1: ...Lumishade Product Manual ...

Страница 2: ... For seamless indoor outdoor living conveniently walk through the individual fabric vanes whether they are opened or closed Easy Breezy Free from noisy connecting chains and bottom weights Lumishade operates quietly and softly settles back into position Two Operating Options Available with two operating options Chain and Cord or Traversing Wand Lumishade fabric can be easily tilted with option to ...

Страница 3: ...ntly detach Lumishade fabric vanes from the track to hand wash Opacity Options Featuring alternating opacity fabric folds light filtering when opened or room darkening when closed Dirt Resistant Treated to effectively repel dust and grime for easy maintenance Fade Resistant All colours meet Australian Standards for colour fastness to resist fading AS2001 4 21 UV Protection UV stabilised fabric mat...

Страница 4: ...4 colours white ivory grey black the beaded chain allows you to rotate the fabric vanes to the desired position while the cord can be used to stack the shade Available in left right and split stack TRAVERSING WAND OPERATION For a cordless and enhanced child safe solution opt for the Traversing Wand operation available in 4 colours white anodised gunmetal and black Using just one hand simply rotate...

Страница 5: ...dup CONTROL PLACEMENT WAND CHAIN CORD Chain Cord Blades stack on same side for split stack choose left or right control Travelling Wand blades stack on side opposite wand Single side stack only BLADE CLOSURE GAP Blades are designed to overlap 25mm for privacy Light leakage may occur due to the closure gap which may increase with the length of the blade The closure gap is most visible when viewed f...

Страница 6: ...00MM REVEAL DEPTH FRONT OF HEADRAIL TO BACK OF VANE 100MM FULLY RECESSED BOX MOUNT 220MM BRACKET SIZE ON FACE FIT 102MM MINIMUM SURFACE MOUNT ON FACE 50MM FABRIC OVERLAP 25MM STACK CALCULATIONS APPROX 10 to 20 OF TRACK WIDTH TRACK DIMENSIONS HEIGHT DEPTH 25MM 46MM LIGHT GAP FROM TOP OF VANE TO BOTTOM OF TRACK 25MM Available Wand Sizes 750mm 1250mm in White Anodised Black Gunmetal ...

Страница 7: ...e fabric when it is comes together in the open position The table below should be used as a guide to calculate the stackback based on the width of the shade 0 2000mm 20 of the shade width 2001 4500mm 15 of the shade width 4500mm 10 of the shade width Please note that the stackback is based on the Std Fabric Range and as with any textile products some variation can be expected based on fabric thick...

Страница 8: ...re wood to wood and add 200mm to total width Drop Measure top to bottom and add 50mm to total drop Reveal Fit Application Width Measure wood to wood Drop Measure top to bottom Deductions Deductions are made to ensure a snug fit of the Lumishade product 3mm is deducted from the total width 15mm is deducted from the drop supplied ...

Страница 9: ...ric is available in only one opacity There will be a distance from the end of the track to the finish position of the wand for the left right stack of wand control The non control end will finish short of the track due to vane requirement for closing The gap for split stack is approximately 10 15mm when the vane is open due to the finish fold of the end vane Due to the fabric s elegant nature the ...

Страница 10: ...if required Available in 6 colours Zinc Stoney beige White Birch White Gunmetal Black TRACK OPTIONS COLOURS Available in 6 colours Anodised White Stoney Beige White Birch Black Gunmetal NOTE All Lumishade are manufactured on the Edge vertical system Lumishade is setup to automatically default to the appropriate hardware colour to match the fabric Selecting your own headrail colour is also availabl...

Страница 11: ...11 P a g e OPEN CORNER INSTALLATION OPTIMUM POSITIONING Based on installation with 102mm Face Fit bracket with total projection of 120mm ...

Страница 12: ...llips head screwdrivers The Lumishade may be installed in Reveal inside the window frame or Face outside the window frame this determines the type of brackets to be used The 102mm mounting bracket is used for all Lumishade blinds If required to extend the Lumishade out from the wall the optional mounting plate can also be used REVEAL FIT The Lumishade should be installed into the recess as far as ...

Страница 13: ...rning Ensure you drill no closer than 25mm from the edge of these surfaces as you may chip or breakout the brick or render INSTALLING THE TRACK Check to see what side the control is on before proceeding Hold track up to the brackets ensuring front edge lip of the track engages into the lip of the bracket twist up and backwards to snap the track on to the bracket Note Longer tracks will require you...

Страница 14: ...faces the back window Click the 2 clear plastic tabs together Hang on last hook INSTALLING THE CORD CHAIN TENSIONER After the blind has been securely mounted to the window mount the cord tensioner to the reveal of the window opening inside mount or to the face of the wall outside mount Determine the correct mounting option as shown below Important Locate the tensioner as close to the window as pos...

Страница 15: ...h or feather duster is sufficient also 2 There can be significant variations between fabrics used in Lumishade therefore we recommend that you clean a small area as a test first 3 Proper care and maintenance will increase the life of your investment The surface of Lumishade fabric and tracks will collect a layer of dust over time Lumishade fabric can be lightly hand washed and dried and can also b...

Страница 16: ...ral times to ensure it opens and closes correctly The Cord Traverses the vanes clear of the window allowing access for opening a window or cleaning The Wand Controls the tilting of the Lumishade and traverses the vanes clear of the window allowing access for opening closing or cleaning Before traversing the vanes ensure they are tilted opened to the window ...

Страница 17: ...with a cord cleat it is essential that the following installation instructions are adhered to If a cleat is used to secure the cord it must be at least 1600mm above floor level to prevent children from unwinding the cord from the cleat SAFETY DEVICES This pack includes the following child safety devices for control options that use chain and cord Cord Tension Device 28 237 850 Cord Tension Hardwar...

Отзывы: