Installation Settings Guide

In this guide we will describe the advanced 

  installation settings that you can access from 

  KONOz’s main menu. We recommend that  

  an HVAC service professional uses these settings 

  to fine-tune your thermostat’s performance for 

  your home. 
You can access the installation settings by going to 

  the main menu and selecting the gear icon. You 

  will see “IS” on the screen and will be prompted to 

  select “yes” or “no”. Select “yes” to access the

  installation settings. Rotate the knob to view 

  settings and press the knob to confirm. 
Once in the installer settings, rotate the knob to 

change a setting value.  Press the knob to confirm 

the new value and proceed to the next option.
There are three ways to exit the settings:
1. Continue through the remaining settings until you 

   pass setting 99.

2. Press and hold the knob for 3 seconds after you 

   confirm any changes to your settings.

3. Wait 60 seconds after you confirm any changes 

   to your settings.

Installation Settings Guide

System Type & Configuration

You will first see your current system type and configuration – confirm by pressing the knob 

    and then you will begin navigating through the available settings. 

HVAC system type

  F = Furnace

  HP = Heat Pump

Available System 

Modes

HVAC system subtype

Furnace Systems
  ELEC: Electric fan. Thermostat calls fan 

   to run with heat
  GAS: Gas fan. Thermostat does not call 

   fan to run with heat
  BOIL: Boiler. No fan connected to 

   heating system

Heat Pump
  o: Changeover valve = O
  b: Changeover valve = B

All manuals and user guides at all-guides.com

all-guides.com

Содержание KONOz

Страница 1: ...next option There are three ways to exit the settings 1 Continue through the remaining settings until you pass setting 99 2 Press and hold the knob for 3 seconds after you confirm any changes to your...

Страница 2: ...ration temperature and the offset value to remove calibration make sure that the offset value is set to 0 03 Available HVAC Modes Heat Only Heat Cool KONOz uses terminal detection to identify your sys...

Страница 3: ...mum Heat Limit Default Temperature 45 F Use this setting to set a minimum temperature limit for your heating system The minimum heat limit range is from 60 F 15 C to as low as 45 F 7 C Note Not availa...

Страница 4: ...Gas Furnace Electric Furnace Boiler No Fan and Heat Pump See step 09 below for additional options when selecting Heat Pump 09 System Type Heat Pump If you selected heat pump during 8 you will then hav...

Страница 5: ...C systems can safely and efficiently switch on and off You can either select a 5 minute or a 2 minute off time During normal operation the hourglass icon indicates that the minimum off time is tempora...

Страница 6: ...to choose between 12 hour am pm time display or 24 hour time display Note This setting not available with battery only power 15 Backlight Use this setting to choose between a backlight auto off settin...

Страница 7: ...ys 98 Compressor Bypass Use this setting to temporarily disable the minimum on off time protection If you set compressor bypass protection to yes then your system will switch heating and cooling on of...

Страница 8: ...control of KONOz When locked press and hold the knob for 10 seconds to unlock Power Cycle Remove KONOz from its base and locate the black reset button on the back of the thermostat Press and hold this...

Отзывы: