EMC and safety requirements
The StarGuide Maxi led-unit is fully compliant to the LVD and EMC directive
of the European council, if used in a properly designed setup.
The StarGuide MAXI led-unit is only intended to be used in lighting
applications, and as such, the complete assembly of led unit and power
supply needs to be fully compliant with following harmonized standards:
LVD requirements of the power supply:
•
EN 60598: general requirements of lighting equipment.
EMC requirements of the power supply:
Immunity according to:
•
EN 61547:2009 (General EMC immunity requirements lighting eq.)
•
EN 61000-4-1:2006 (General immunity testing techniques)
•
EN 61000-4-2:2008 (ESD immunity test)
•
EN 61000-4-3:2006 + A1:2007 (Radiated immunity test)
•
EN 61000-4-4:2004 (Fast transients and burst immunity)
•
EN 61000-4-5:2005 (Surge immunity test)
•
EN 61000-4-6:2008 (Conducted immunity test)
•
EN 61000-4-8:1993 (Magnetic field immunity test)
•
EN 61000-4-11:2004 (Voltage variations immunity test)
•
EN 61000-6-1:2005 (Generic standards for immunity)
Emission according to:
•
EN 61000-3-2:2005+A1:2008+A2:2009 (Harmonics emission
test<16A)
•
EN 61000-3-3:2008 ( voltage changes limits< 16A)
•
EN 55015:2006+A2:2009 (Con radiated emission lighting
equipment)
To achieve this compliance, a proper power supply must be supplied. In
case of doubts, contact your point of sale.