Ethernet/IP bus interface for DIOLINE20 Vers. 1.00
Functional description
37/45
4.3.8 Monitor program
The module contains a monitor program for configuration and diagnostics of the module. This monitor
program communicates with a terminal application through dialogs and commands.
Physical communication is via the serial interface of the module, whereby the following interface
parameters must be set on the other side:
Baud rate
9600 bd
No. of data bits
8
No. of stop bits
1
No. of parity bits
0
Handshake
no
The monitor provides the following commands (the dialogue language is English):
Command
Parameter
Description
ipconfig
ip [IP address] |
mask [network
mask] |
gw [gateway
address]
Display or set defaults of the network configuration (IP address,
network mask, gateway address)
factory
-
Reset network configuration to factory settings
reset
-
Restart the module (warm start))
status
-
Display status of module