background image

Installing the Dosing Pump

Set up information

16

Stepper Motor-driven Diaphragm Dosing Pump 

MEMDOS SMART LB

© Lutz-Jesco GmbH 2014

Operating Instructions

BA-10100-02-V02

7  Installing the Dosing Pump

7.1  Set up information

When installing, follow the basic principles below:

The valves must be vertical: Discharge valve at top, suction valve at 
bottom. in this connection, pay attention to the arrow on the dosing 
head. The dosing head must be aligned such that the arrow points 
vertically upwards.

You should install the dosing pump at a convenient height for opera-
tion.

It must not be installed under the ceiling.

The frame of foundation for fixing the dosing pump must not be 
subjected to jolts. The pump must be vibration-free and stable.

There must be enough free space in the area of the dosing head and 
the suction and discharge valves for these parts to be easily disman-
tled if required. The entire space requirement for installation and 
maintenance is approximately 1 m².

The distance from the sides of the dosing pump to the wall or other 
dosing pumps or equipment must be at least 3 cm. There must be a 
guaranteed flow of circulating air.

The maximum ambient temperature must be complied with, see 
“Operating conditions and limits” on page 12. If necessary, radiated 
heat from surrounding equipment must be screened.

Avoid exposure to direct sunlight.

The dosing pump is not intended for use out of doors unless appro-
priate protective measures have been taken to prevent dust and 
water from entering the housing.

For the dimensions of the fastening holes, refer to Chapter ”Dimen-
sions“ (see page 14).

The tightening torque for the fastening bolts is 1.5 - 2 Nm.

7.2  Installation examples

7.2.1 Installation on a wall console

Fig. 7-1: Installation on a wall console

To reduce the structure-borne noise, the dosing pump is bolted to the 
wall bracket using rubber elements. The materials necessary for this are 
included with the wall bracket.

7.2.2 Installation on the wall

Fig. 7-2: Installation on the wall

The dosing pump can be mounted to the floor or directly to the wall 
without the need for additional elements. Turn the dosing head appro-
priately to ensure the flow direction of the medium through the dosing 
head.

DANGER

Danger to life due to electric shock!

Electrically conductive liquid can enter pump housings, cable screw 
connections and mains connectors.

Make sure that all protective measures comply at least with the 
requirements of protection class IP65.

Always set up the dosing pump such that water cannot enter the 
housing.

CAUTION

Danger of personal injury and material damage!

A dosing pump that is difficult to access represents a danger due to 
incorrect operation and faulty maintenance.

Install the dosing pump such that it is accessible at all times.

Содержание MEMDOS SMART LB

Страница 1: ...inal Operating Instructions Lutz Jesco GmbH 2014 BA 10100 02 V02 Stepper Motor driven Diaphragm Dosing Pump MEMDOS SMART LB Operating Instructions Read the operating instructions The user is responsib...

Страница 2: ......

Страница 3: ...a 13 Other data 13 6 Dimensions 14 MEMDOS SMART LB 5 10 14 MEMDOS SMART LB 15 20 15 7 Installing the Dosing Pump 16 Set up information 16 Installation examples 16 8 Hydraulic installations 17 Dimensio...

Страница 4: ...ing signs represent the type and source of a danger 1 4 Identification of warnings Warnings are intended to help you recognise risks and avoid negative consequences This is how warnings are identified...

Страница 5: ...eck that all the screw connections have been tightened cor rectly and are leak proof WARNING Caustic burns or other burns through dosing media While working on the dosing head valves and connections y...

Страница 6: ...fication Any personnel who work on the dosing pump must have appropriate special knowledge and skills Anybody who works on the dosing pump must meet the conditions below Attendance at all the training...

Страница 7: ...iling point of the respective medium The materials of the dosing pump and hydraulic parts of the system must be suitable for the dosing medium that is used In this connec tion note that the resistance...

Страница 8: ...es that are difficult to access Delivery of dosing media for which the system is not designed Delivery of particulate or contaminated dosing media Inadequate protective clothing or none at all 3 6 6 I...

Страница 9: ...for external start stop 4 2 Scope of delivery Please compare the delivery note with the scope of delivery The following items are part of the scope of delivery Dosing pump MEMDOS SMART LB One set each...

Страница 10: ...he pressure in the dosing head the suction valve closes and the dosing medium flows through the discharge valve from the dosing head into the pressurised pipe 4 5 Ratings plate type label There is inf...

Страница 11: ...o run the pressure stroke and suction stroke at different speeds For low supply rates for example the dosing pump performs the suction stroke at the maximum speed and adjusts the speed of the pressure...

Страница 12: ...nufacturer With a viscosity of 300 mPas and above you must use spring loaded valves If the viscosity is above 1000 mPas this must be checked individually Information Value MEMDOS SMART LB size 5 10 15...

Страница 13: ...ead made of stainless steel 1 4571 C 0 80 Table 5 3 Permitted media temperatures Information Value MEMDOS SMART LB size 5 10 15 20 Voltage supply 110 240 V 10 5 50 60 Hz Power consumption W 25 Table 5...

Страница 14: ...osing head made of PVC PP or PVDF all dimensions in mm Fig 6 2 Dimensioned drawing of MEMDOS SMART LB 5 10 with dosing head made of stainless steel 1 4571 all dimensions in mm Connection Material Size...

Страница 15: ...15 20 Fig 6 3 Dimensioned drawing of MEMDOS SMART LB 15 20 with dosing head made of PVC PP PVDF or stainless steel 1 4571 all dimensions in mm 7 3 2 5 1 0 2 4 8 5 7 1 3 5 1 8 1 L L 84 70 6 5 100 116 1...

Страница 16: ...rounding equipment must be screened Avoid exposure to direct sunlight The dosing pump is not intended for use out of doors unless appro priate protective measures have been taken to prevent dust and w...

Страница 17: ...ing media The materials of the dosing pump and hydraulic parts of the system must be suitable for the dosing medium that is used Should this not be the case the dosing media may leak Depending on the...

Страница 18: ...ed vertically The suction valve must always point downwards Accordingly arrow and pressure valve always point upwards This is irrespective of the positioning of the dosing head to the drive 8 4 Hydrau...

Страница 19: ...on the grommet of connection piece 6 Screw the union nut onto the valve of the dosing pump Hose clip connected 8 4 2 Making the bonded connection Fig 8 4 Bonded connection Perform the following workin...

Страница 20: ...the downward opening Fig 8 6 Openings of the leakage drain 8 6 Connecting the dosing head venting facility The dosing heads of the MEMDOS SMART LB 5 and LB 10 have an inte grated dosing head venting u...

Страница 21: ...unctions Dosing the medium into a main line Preventing flowback into the pressure line through a non return valve Notes on assembly Double ball injection nozzles must be installed into the main line v...

Страница 22: ...o high Notes on assembly The line for returning dosing medium from the pressure relief valve must be routed to the dosing tank or to a collecting pan The pressure in the dosing tank must not be too hi...

Страница 23: ...liquid column due to too high acceleration However pulsation dampeners also have important safety functions since they prevent pressure peaks from arising that lead to piping vibrating and cause them...

Страница 24: ...air in the suction line and the dosing head in dosing systems with frequent downtimes Further advantages resulting from priming aids preventing cavitation in the suction line gas removal optical dosi...

Страница 25: ...e dosing head must be rinsed regularly to prevent depositing To do this you install a feed line for the rinsing medium water in the suction side installation Fig 8 15 Dosing of suspensions Dosing tank...

Страница 26: ...of the dosing tank in the case of a diaphragm rupture or pipe breakage Impermissibly high forces in the pump transmission that occur when dosing pumps receive the dosing medium directly from the pres...

Страница 27: ...ply This means that dosing medium can escape Depending on the type and haz ardousness of the dosing medium this can result in damage to property or to injury Install an emergency stop switch or integr...

Страница 28: ...from Lutz Jesco GmbH No liability is accepted for cables from other manufacturers Removing the conductive rubber band Fig 9 3 Conductive rubber band in connection socket 1 Remove the conductive rubber...

Страница 29: ...on The scale of the stroke frequency setting shows the value of the setting in percent from 0 stopped to 100 maximum possible stroke frequency Fig 10 1 Stroke frequency setting In terms of the stroke...

Страница 30: ...c parts Never look into open ends of plugged pipelines and valves CAUTION Danger of personal injury and material damage Dosing medium can escape if you loosen connections on the dosing head e g for ve...

Страница 31: ...in the metering container 3 Vent the dosing pump see 11 1 1 Venting the dosing pump 4 Set the stroke frequency to 0 5 Connect the power supply to dosing pump and set the stroke frequency to 100 within...

Страница 32: ...ing working steps 1 Unplug the dosing pump s mains plug from the power supply 2 Disconnect all electrical connections 3 Depressurize all the hydraulic parts in the system 4 Unplug all the hydraulic co...

Страница 33: ...sportation Should the unit be sent back to the manufacturer please follow chap ters Declaration of harmlessness see page 42 and Warranty appli cation see page 44 11 7 Disposal of old units The waste u...

Страница 34: ...all the screw connections have been tightened cor rectly and are leak proof CAUTION Danger of personal injury and material damage The dosing pump can generate a pressure that is many times the rated o...

Страница 35: ...gm flange so that the new diaphragm is not affected by dosing medium residues You have slightly greased the diaphragm thread e g using Molykote Longterm W2 1 Screw the diaphragm manually in the clockw...

Страница 36: ...the suction line Shut off valves closed Open the shut off valves Inspect the dosing pump for possible damage Suction head too high Set the dosing pump to feed or reduce the suction head Install a pri...

Страница 37: ...all a back pressure valve in the pressure line Pressure peaks due to accel eration with long suction lines Install a suction pressure regu lator Table 13 4 Type of fault Delivery rate varies Possible...

Страница 38: ...nstall a suction pressure regu lator The materials are not suitable for the dosing medium being used Check the resistance of the materials Diaphragm not screwed up to the end stop on the diaphragm rod...

Страница 39: ...arts kit containing 1 diaphragm 1 set of dosing head screws 1 set of washers only MEMDOS SMART LB 15 20 14 2 Dosing head spare parts kits including valves Spare parts set dosing head including screws...

Страница 40: ...ic back pressures These delivery capacities were determined on the manufacturer s test stands They apply at 20 C 68 F for water at 100 stroke frequency The delivery capacity depends on the medium dens...

Страница 41: ...uran a e de sa de das directivas CE indicadas A presente declara o perde a sua validade em caso de altera o ao equipamento n o autorizada por n s EN EC Declaration of Conformity We hereby certify that...

Страница 42: ...on for repair Dosing medium Description Irritating F Yes F No Properties Corrosive F Yes F No We hereby certify that the product has been cleaned thoroughly inside and outside before returning that it...

Страница 43: ...43 Lutz Jesco GmbH 2014 Subject to technical changes 140410 Stepper Motor driven Diaphragm Dosing Pump MEMDOS SMART LB Operating Instructions BA 10100 02 V02 Notes...

Страница 44: ...y application filled out Sender Company Phone Date Address Contact person Manufacturer order no Date of delivery Device type Serial number Nominal capacity nominal pressure Description of fault Servic...

Страница 45: ...13 Prohibited dosing media 7 E EC Declaration of Conformity 41 Electrical installation 27 Electrical specifications 13 External On Off via Release input 32 F Foreseeable misuse 7 Function description...

Страница 46: ...uspensions 25 System piping 18 T Technical specifications 12 Temperature Permitted ambient temperature 12 Permitted media temperatures 13 Tighten up dosing head bolts 35 Trained persons 6 Transportati...

Страница 47: ......

Страница 48: ...a Lutz Jesco GmbH Aredstra e 7 2 2544 Leobersdorf Austria Tel 43 2256 62180 Fax 43 2256 6218062 E mail info lutz jesco at Website www lutz jesco at Middle East Lutz Jesco Middle East FZE P O Box 9614...

Отзывы: