Troubleshooting
List of control unit messages
54
Solenoid-Diaphragm Dosing Pump
MAGDOS LP
© Lutz-Jesco GmbH 2014
Operating Instructions
BA-10231-02-V03
13.1.7 Loud noises on the dosing pump
13.2 List of control unit messages
Possible cause
Remedy
The drive magnet's stop
damper is worn-out
Contact the manufacturer.
Table 13-7: Type of fault: Loud noises on the dosing pump
Display
Description in
"Messages" menu
Explanation
Error code
Messages Menu
Stop the dosing
pump
Fault signalling
relay
-
Restart pump
Reset to factory settings
#00
Yes
Yes
Tank at minimum
level
Minimum level
Level monitoring messages
#01
No
Yes
Tank empty
Empty level
#02
Yes
Yes
Flowcon error
Dosing control
Flowcon reports faulty strokes
Dosing pump continues to run
#05
No
Yes
Flowcon stop
Dosing control
Flowcon reports faulty strokes
Dosing pump stopped
#05
Yes
Yes
Release input stop
No external release
Dosing pump waiting for external
On/Off
#06
Yes
Yes
Diaphragm rupture
stop
Diaphragm rupture
Leakage sensor reports diaphragm
rupture
#07
Yes
Yes
Analogue input
error
20mA input error
No signal or faulty signal at the
analogue input
#08
Yes
Yes
Stop
Manual stop
Dosing pump stopped by user
#09
Yes
Yes
Set-up error
General unit error
Internal hardware fault
#10
Yes
Yes
Stroke error
General unit error
Internal hardware fault
#10
No
Yes
-
Excess temperature
Temperature monitoring
#11
Yes
Yes
Offline
Offline
No signal in network operation or
faulty data transfer
#12
Yes
Yes
Battery error
Clock
Time error stops dosing pump in
batch operation, timer type
#13
Yes
Yes
Stroke buffer
maximum
Stroke buffer full
Stroke buffer is too small
#14
No
No
Mains supply error
Voltage error
Overvoltage
#15
Yes
Yes
-
Alarm list deleted
Delete list of messages
#18
No
No
Table 13-8: List of control unit messages