Operation
Operating modes
47
© Lutz-Jesco GmbH 2014
Subject to technical changes.
140327
Solenoid-Diaphragm Dosing Pump
MAGDOS LP
Operating Instructions
BA-10231-02-V03
3.
Use the
or
key to choose the
Start time 1
menu item and
press
Setup
.
4.
Press the
+
key to increment the parameter's value or the
-
key to
decrement it.
5.
Press
OK
.
6.
Using
or
select
Runtime 1
or
Preset strokes 1
and then
press
Setup
.
7.
Press the
+
key to increment the parameter's value or the
-
key to
decrement it.
8.
Press
OK
.
9.
Use the
or
key to choose the
Capacity
menu item and press
Setup
.
10.
Press the
+
key to increment the parameter's value or the
-
key to
decrement it.
11.
Press
OK
.
The dosing pump displays the current configuration of this oper-
ating mode's parameters (Menu 3.41).
12.
If required, also program the dosing procedure 2 with the parame-
ters
Start time 2
,
Runtime 2
or
Preset strokes 2
.
13.
Use the
or
key to choose the
Mo-Su
menu item and press
Setup
.
14.
Press
Next
to select a weekday.
15.
Press
1/2/-
to program the dosing procedures for the selected
weekday. The following settings can be made:
16.
Press
OK
.
The dosing pump displays the current configuration of this oper-
ating mode's parameters (Menu 3.41).
Fig. 11-13: Configuring the batch mode mode Timer
In this example, the dosing procedure 1 starts on Monday and on Friday
at 9 o'clock in the morning. Dosing procedure 1 runs for 10 minutes at
50% of the stroke frequency (Y 50%). Dosing procedure 2 starts on
Thursday and on Friday at 4 o'clock in the afternoon. Dosing procedure
2 runs for 100 strokes at 50% stroke frequency.
17.
Press
OK
.
The dosing pump displays the start screen of
Batch mode.
Fig. 11-14: Start-up display of the batch mode mode Timer
The start-up display of the batch mode mode
Timer
shows the
remaining time until the next start as well as the current time.
Dosing procedures programmed.
11.2.4.5 Starting the dosing pump
If batch mode mode
Start/Stop
is set:
1.
Press
Start
.
2.
Press
Start
again.
The dosing pumps starts dosing immediately. The system auto-
matically calculates the resulting delivery capacity and displays it.
Dosing pump has started.
If batch mode is set to
Ext.
Start
:
1.
Press
Start
.
2.
Supply a pulse to the pulse input of the dosing pump.
The dosing pumps starts dosing immediately. The system auto-
matically calculates the resulting delivery capacity and displays it.
Dosing pump has started.
If batch mode mode
Interval
is set:
Press
Start
.
The dosing pump displays the time remaining until the set interval
is reached. After the time has expired, the pump starts dosing.
Dosing pump has started.
If batch mode mode
Timer
is set:
Press
Start
.
The dosing pump starts dosing when one of the set days of the
week and one of the set start times are reached.
Dosing pump has started.
11.2.4.6 Stopping the dosing pump
Press
Stop
.
Dosing pump has stopped.
Setting
Explanation
1
Dosing procedure 1 will be carried out on the selected
weekday.
2
Dosing procedure 2 will be carried out on the selected
weekday.
3
Dosing procedures 1 and 2 will be carried out on the
selected weekday.
-
No dosing procedure will be carried out on the selected
weekday.
Please note that, if setting 3 is chosen, dosing procedure 1
and dosing procedure 2 must be programmed with a suffi-
cient time gap between them If one dosing procedure has not
finished before the start time of the other one, the first will be
interrupted and the other dosing procedure started.
i
Batch mode
Menu
3.41
OK
Setup
Mode
Start 1 09:00 10 min
Start 2 16:00 100 Strokes
Y 50% Mo-Su 1 - - 2 3 - -
Batch mode
Menu
Start
Setup
14:50
Next start
1 h : 10 min
0%
Содержание MAGDOS LP
Страница 2: ......
Страница 70: ...70 Solenoid Diaphragm Dosing Pump MAGDOS LP Lutz Jesco GmbH 2014 Operating Instructions BA 10231 02 V03 Notes ...
Страница 75: ......