8.2 System piping
The system piping must not exert any force on the connections and
valves of the dosing pump.
This means that steel piping should be connected to the dosing
pump by means of flexible pipe sections.
The nominal diameters of the pipework and the installed fittings
should be rated the same as or greater than the nominal diameters
of the dosing pump's suction and discharge valves.
The suction line should be kept as short as possible.
You should avoid intertwined hoses.
Avoid loops, since air bubbles can collect.
8.3 Aligning the dosing head
Fig. 8-1: Aligning the dosing head
When connecting the dosing lines to the dosing pump, you must
observe the direction of through-flow (see arrow
).The dosing head
must be aligned vertically.
The suction valve
must always point downwards. Accordingly, arrow
and pressure valve
always point upwards. This is irrespective of
the positioning of the dosing head to the drive.
8.4 Hydraulic connections
8.4.1 Connecting hose clips
Choose the hose connection according to the condition of the hose
(material, inner diameter, wall thickness) in order to ensure maximum
pressure resistance.
8.4.1.1 Sizes 4/6 and 6/9
Fig. 8-2: Hose clips 4/6 and 6/9 (internal and external diameters in mm)
Perform the following working steps:
1.
Cut the hose
to length neatly and at an exact right angle.
2.
Place a gasket that is suitable for the dosing medium between the
connection
and the valve.
3.
Screw the connecting piece
to the dosing pump's valve using
the union nut
.
4.
Thread the union nut
and the clamping ring
onto the hose.
5.
Plug the hose
all the way in to the grommet of connection
piece
.
6.
Push the clamping ring
onto the grommet of connection piece
and screw it to the union nut
.
7.
Carry out the same procedure with the connection to the dosing
pump's other valve.
Hose clip connected.