Страница 1: ...marks a step forward for you into the field of precision measurement Although this METER is a complex and delicate instrument its durable structure will allow many years of use if proper operating tec...

Страница 2: ...eparation 9 4 2 Unit selection Acc Velocity Displacement selection 10 4 3 Function selection 11 4 4 Zero adjustment procedures 12 4 5 Data Hold 13 4 6 Data Record Max Min reading 13 4 7 LCD Backlight...

Страница 3: ...desired reading Memory function to record maximum and minimum reading with recall Separate vibration probe with magnetic base easy operation Real time SD memory card Datalogger it Built in Clock and...

Страница 4: ...52 mm x 38 mm LCD with green backlight ON OFF Measurement Velocity Acceleration Displacement Function Acceleration Velocity RMS Peak Max Hold Displacement p p peak peak Max Hold p p Unit Measurement M...

Страница 5: ...ond Setting range but memory data may loss Manual Push the data logger button once will save data one time Set the sampling time to 0 second Manual mode can also select the 1 to 99 position Location n...

Страница 6: ...ional Power Current Normal operation w o SD card save data and LCD Backlight is OFF Approx DC 15 mA When SD card save the data and LCD Backlight is OFF Approx DC 36 mA Weight Meter 515 g 1 13 LB Probe...

Страница 7: ...nit g 1 g 9 8 m s 2 Range 0 05 to 20 39 G Resolution 0 01 G Accuracy 5 2 d reading 160 Hz 80 Hz 23 5 Calibration 50 m S 2 160 Hz Point Unit ft s 2 Range 2 to 656 ft s 2 Resolution 1 ft s 2 Accuracy 5...

Страница 8: ...o 19 99 cm s Resolution 0 01 cm s Accuracy 5 2 d reading 160 Hz 80 Hz 23 5 Calibration 50 mm s 160 Hz Point Unit inch s Range 0 02 to 7 87 inch s Resolution 0 01 inch s Accuracy 5 2 d reading 160 Hz 8...

Страница 9: ...Unit inch Range 0 078 inch Resolution 0 001 inch Accuracy 5 2 d reading 160 Hz 80 Hz 23 5 Calibration 0 141 mm 160 Hz Point Remark p p To measure the Peak to Peak value Max Hold p p To measure and up...

Страница 10: ...Button Sampling time check Button Zero Button Max hold reset Button 3 7 BNC Input Socket 3 8 SD Card Socket 3 9 RS 232 Output Terminal 3 10 Reset Button 3 11 DC 9V Power Adapter Input Socket 3 12 Bat...

Страница 11: ...he Input socket of vibration sensor 3 18 Fig 2 Remark 1 If the surface material of measuring article is not the ferrous material hold the vibration sensor by hand touch the sensor to the surface of th...

Страница 12: ...button the Display will show the following units according Acceleration Velocity Displacement in sequence Measurement Unit Acceleration m s 2 g ft s 2 LCD show ACC Velocity mm s cm s inch s LCD show...

Страница 13: ...Max HOLD by pressing the Function Button 3 3 Fig 1 continuously not release the button until the Display will show the desiring function RMS Max HOLD Peak then release the Function Button 3 3 Fig 1 Th...

Страница 14: ...battery power change meter used for a long time or other reasons The display value may exist not zero value few digits in case of no signal into the Vibration Sensor General speaking those not zero va...

Страница 15: ...l on the display a Press the REC Button 3 4 Fig 1 once the REC MAX symbol along with the maximum value will appear on the display If intend to delete the maximum value just press the Hold Button 3 3 F...

Страница 16: ...D card into the SD card socket 3 8 Fig 1 The front panel of the SD card should face against the the down case It recommend use memory card s capacity is 4 GB b SD card Format If SD card just the first...

Страница 17: ...it should change the Decimal character at first details of setting the Decimal point refer to Chapter 7 2 page 22 5 2 Auto Datalogger Set sampling time 1 second a Start the datalogger Press the REC B...

Страница 18: ...er During pause the Datalogger press the REC Button 3 4 Fig 1 continuously at least two seconds the REC indication will be disappeared and finish the Datalogger 5 3 Manual Datalogger Set sampling time...

Страница 19: ...nds the REC indication will be disappeared and finish the Datalogger 5 4 Check time information During the normal measurement not execute the Datalogger If press Time check Button 3 5 Fig 1 once the l...

Страница 20: ...save to the VBB01001 XLS until Data column reach to 30 000 columns then will generate a new file for example VBB01002 XLS 3 Under the folder VBB01 if the total files more than 99 files will generate...

Страница 21: ...SD card into the SD card adapter then connect the SD card adapter into the computer 3 Power ON the computer and run the EXCEL software Down load the saving data file for example the file name VBB01001...

Страница 22: ...the Advanced Setting mode then press the Next Button 3 3 Fig 1 once a while in sequence to select the eight main function the lower display will show dAtE Set clock time Year Month Date Hour Minute S...

Страница 23: ...1 to adjust the value Setting start from Year value After the desired value is set press the Enter Button 3 4 Fig 1 once will going to next value adjustment for example first setting value is Year th...

Страница 24: ...upper value to USA or Euro USA Use as the Decimal point with default Euro Use as the Decimal point with default 2 After select the upper text to USA or Euro press the Enter Button 3 4 Fig 1 will save...

Страница 25: ...n 3 4 Fig 1 will save the setting function with default function with default 7 5 Set sampling time seconds When the lower display show SP t 1 Use the Button 3 6 Fig 1 or Button 3 5 Fig 1 to adjust th...

Страница 26: ...apter into DC 9V Power Adapter Input Socket 3 11 Fig 1 The meter will permanent power ON when use the DC ADAPTER power supply The power Button function is disable 9 BATTERY REPLACEMENT 1 When the left...

Страница 27: ...method During the power on use a pin to press the Reset Button 3 10 Fig 1 once a while will reset the circuit system 11 RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3 5...

Страница 28: ...D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicates the following status D15 Start Word D14 4 D13 1 D12 D11 Annunciator for Display 92 97 mm s 93 cm s 95 inch s 98 mm 94 inch 96 g 57 D10 0 D9 Decimal P...

Страница 29: ...severity mm s are determined The classifications for each machine group are specified as follows Small machines especially production electrical motors of up to 15 KW Group K Good 0 to 0 71 mm s Acce...

Страница 30: ...ons Group T Good 0 to 2 80 mm s Acceptable 2 81 to 7 10 mm s Still permissible 7 11 to 18 0 mm s Dangerous 18 mm s 13 SENSITIVITY RELATIVE to the reference sensitivity at 80 Hz according ISO 2954 Freq...

Страница 31: ...ard structure already get patent or patent pending in following countries Germany JAPAN Nr 20 2008 016 337 4 TAIWAN 3151214 M 358970 CHINA M 359043 ZL 2008 2 0189918 5 USA ZL 2008 2 0189917 0 Patent p...