background image

SD card real time datalogger

+ Type K/J thermometer

LIGHT METER

Model : LX-1128SD

Your purchase of this LIGHT METER with SD CARD
DATALOGGER marks a step forward for you into the field of
precision measurement. Although this METER is a complex and
delicate instrument, its durable structure developed. Please
read the following instructions carefully and always keep this
manual within easy reach.

       OPERATION MANUAL

Содержание LX-1128SD

Страница 1: ...HT METER with SD CARD DATALOGGER marks a step forward for you into the field of precision measurement Although this METER is a complex and delicate instrument its durable structure developed Please re...

Страница 2: ...Measurement 7 4 2 Data Hold 9 4 3 Data Record Max Min reading 9 4 4 LCD Backlight ON OFF 10 5 DATALOGGER 10 5 1 Preparation before execute datalogger function 10 5 2 Auto Datalogger Set sampling time...

Страница 3: ...logger function it can set the different position location No position 1 to position 99 Innovation and easy operation computer is not need to setup extra software after execute datalogger just take aw...

Страница 4: ...Time Sampling time can set to 1 second Setting range but memory data may loss Manual Push the data logger button once will save data one time Set the sampling time to 0 second Manual mode can also sel...

Страница 5: ...Supply A Alkaline or heavy duty DC 1 5 V battery UM3 AA x 6 PCs or equivalent A DC 9V adapter input AC DC power adapter is optional Power Current Normal operation w o SD card save data and LCD Backli...

Страница 6: ...1 999 LUX LUX 20 000 LUX 1 800 19 990 LUX auto range 100 000 LUX 18 000 99 900 LUX 200 Ft cd 0 186 0 Ft cd Feet candle 2 000 Ft cd 167 0 1 860 0 Ft cd auto range 10 000 Ft cd 1 670 0 9 290 7 Ft cd Ra...

Страница 7: ...0 5 50 1 to 100 0 0 4 1 0 1 58 0 to 2372 0 0 4 1 58 1 to 148 0 0 4 1 8 Type J 0 1 50 0 to 1200 0 0 4 0 5 50 1 to 100 0 0 4 1 0 1 58 0 to 2192 0 0 4 1 58 1 to 148 0 0 4 1 8 Above specification tests u...

Страница 8: ...6 Logger Button Button Sampling time check Button Zero Button 3 7 Probe input socket 3 8 Type K J thermometer socket 3 9 SD card socket 3 10 RS 232 Output Terminal 3 11 Reset Button 3 12 DC 9V Power A...

Страница 9: ...tton 3 3 Fig 1 continuously not release the button the Display will show the following text in sequence LIgHt Light meter tP Type K J Thermometer Until the Display show the desired mode Function just...

Страница 10: ...t Sensor 3 19 Fig 1 by Sensor Cover 3 20 Fig 1 the display not show zero value press the Zero Button Logger Button 3 6 Fig 1 3 seconds Display will show zero value Upon completion remove the sensor co...

Страница 11: ...on the display 2 With the REC symbol on the display a Press the REC Button 3 4 Fig 1 once the REC MAX symbol along with the maximum value will appear on the display If intend to delete the maximum val...

Страница 12: ...d should face against the the down case b SD card Format If SD card just the first time use into the meter it recommend to make the SD card Format at first please refer chapter 7 8 page 19 c Time sett...

Страница 13: ...nable refer to Chapter 7 4 page 18 b Pause the datalogger During execute the Datalogger function if press the Logger Button 3 6 Fig 1 once will pause the Datalogger function stop to save the measuring...

Страница 14: ...5 Fig 1 the lower no position no will flashing It can use the Button 3 6 Fig 1 or Button 3 5 Fig 1 to set the measuring position 1 to 99 for example room 1 to room 99 to identify the measurement loca...

Страница 15: ...the first time to execute the Datalogger under the route LXA01 will generate a new file name LXA01001 XLS After exist the Datalogger then execute again the data will save to the LXA01001 XLS until Dat...

Страница 16: ...SD card into the SD card adapter then connect the SD card adapter into the computer 3 Power ON the computer and run the EXCEL software Down load the saving data file for example the file name LXA01001...

Страница 17: ...e Next Button 3 3 Fig 1 once a while in sequence to select the eight main function the lower display will show dAtE Set clock time Year Month Date Hour Minute Second dEC Set SD card Decimal character...

Страница 18: ...st the value Setting start from Year value After the desired value is set press the Enter Button 3 4 Fig 1 once will going to next value adjustment for example first setting value is Year then next to...

Страница 19: ...er value to bASIC or Euro bASIC Use as the Decimal point with default Euro Use as the Decimal point with default 2 After select the upper text to bASIC or Euro press the Enter Button 3 4 Fig 1 will sa...

Страница 20: ...N 2 After select the upper text to yES or no press the Enter Button 3 4 Fig 1 will save the setting function with default 7 5 Select the Thermometer to Type K or Type J When the lower display show tYP...

Страница 21: ...7 Set sampling time SecondS When the lower display show SP t 1 Use the Button 3 6 Fig 1 or Button 3 5 Fig 1 to adjust the value 1 2 5 10 30 60 120 300 600 1800 3600 seconds 2 After teh Sampling value...

Страница 22: ...nput Socket 3 12 Fig 1 The meter will permanent power ON when use the DC ADAPTER power supply The power Button function is disable 9 BATTERY REPLACEMENT 1 When the left corner of LCD display show it i...

Страница 23: ...method During the power on use a pin to press the Reset Button 3 11 Fig 1 once a while will reset the circuit system 11 RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3 5...

Страница 24: ...h digit indicates the following status D0 End Word D1 D8 Display reading D1 LSD D8 MSD For example If the display reading is 1234 then D8 to D1 is 00001234 D9 Decimal Point DP position from right to t...

Страница 25: ...tra fast response naked bead thermocouple suitable for many general purpose application Thermocouple Measure Range 50 to 900 Probe 50 to 1650 Type K TP 02A Dimension 10cm tube 3 2mm Dia Thermocouple M...

Страница 26: ...ard structure already get patent or patent pending in following countries Germany Nr 20 2008 016 337 4 JAPAN 3151214 TAIWAN M 358970 M 359043 CHINA ZL 2008 2 0189918 5 ZL 2008 2 0189917 0 USA Patent p...