SD card real time Data Recorder

Type K/J thermometer, Dew point, Wet bulb

HUMIDITY/TEMP. METER

Model : HT-3007SD

Your purchase of this
HUMIDITY/TEMP.
METER with SD CARD

D A T A   R E C O R D E R

marks a step forward for

you into the field of

precision measurement.

A l t h o u g h   t h i s

DATALOGGER is a

complex and delicate

instrument, its durable

structure will allow

many years of use if
p r o p e r   o p e r a t i n g

t e c h n i q u e s   a r e
developed. Please read

t h e   f o l l o w i n g

instructions carefully

and always keep this

manual within easy

reach.

       OPERATION MANUAL

Содержание HT-3007SD

Страница 1: ...R marks a step forward for you into the field of precision measurement A l t h o u g h t h i s DATALOGGER is a complex and delicate instrument its durable structure will allow many years of use if p r...

Страница 2: ...selection 7 4 2 Data Hold 9 4 3 Data Record Max Min reading 9 4 4 LCD Backlight ON OFF 10 5 DATALOGGER 10 5 1 Preparation before execute datalogger function 10 5 2 Auto Datalogger Set sampling time 1...

Страница 3: ...ition 99 Innovation and easy operation computer is not need to setup extra software after execute datalogger just take away the SD card from the meter and plug in the SD card into the computer it can...

Страница 4: ...data may loss Manual Push the data logger button once will save data one time Set the sampling time to 0 second Manual mode can also select the 1 to 99 position Location no Memory Card SD memory card...

Страница 5: ...er Supply A Alkaline or heavy duty DC 1 5 V battery UM3 AA x 6 PCs or equivalent A DC 9V adapter input AC DC power adapter is optional Power Current Normal operation w o SD card save data and LCD Back...

Страница 6: ...emperature Range 5 to 95 R H Humidity Resolution 0 1 R H Accuracy 70 RH 3 reading 1 RH 70 RH 3 RH Range 0 to 50 32 to 122 Temperature Resolution 0 1 degree Accuracy 0 8 1 5 Dew Point Humidity Range 25...

Страница 7: ...value of Humidity Temperature measurement Type K J thermometer Sensor Resolution Range Accuracy Type Type K 0 1 50 0 to 1300 0 0 4 0 5 50 1 to 100 0 0 4 1 0 1 58 0 to 2372 0 0 4 1 58 1 to 148 0 0 4 1...

Страница 8: ...utton Button Sampling time check Button 3 7 Probe Humidity Temp input socket 3 8 Type K J thermometer socket 3 9 SD card socket 3 10 RS 232 Output Terminal 3 11 Reset Button 3 12 DC 9V Power Adapter I...

Страница 9: ...ew point Humidity c Wet bulb Humidity d Type K J Thermometer Pressing the Function Button 3 3 Fig 1 continuously not release the button the Display will show the following text in sequence rH Humidity...

Страница 10: ...display unit is defaulted to If intend to let the meter s temperature unit default to then please refer chapter 7 6 page 20 4 Dew point Humidity measurement a Function select to Dew point Humidity mea...

Страница 11: ...e Display show the indicator J it is ready for Type J thermometer Remark The meter is defaulted to Type K thermometer If intend to select the Type J thermometer with default please refer chapter 7 5 p...

Страница 12: ...isplay will show the REC symbol only execute the memory function continuously c To exit the memory record function just press the REC button for 2 seconds at least The display will revert to the curre...

Страница 13: ...pe is used the as the decimal point for example 20 6 1000 53 Under such situation it should change the Decimal character at first details of setting the Decimal point refer to Chapter 7 2 page 18 5 2...

Страница 14: ...er During pause the Datalogger press the REC Button 3 4 Fig 1 continuously at least two seconds the REC indication will be disappeared and finish the Datalogger 5 3 Manual Datalogger Set sampling time...

Страница 15: ...inuously at least two seconds the REC indication will be disappeared and finish the Datalogger 5 4 Check time information During the normal measurement not execute the Datalogger If press Time check B...

Страница 16: ...e to the HTA01001 XLS until Data column reach to 30 000 columns then will generate a new file for example HTA01002 XLS 3 Under the folder HTA01 if the total files more than 99 files will generate anew...

Страница 17: ...SD card into the SD card adapter then connect the SD card adapter into the computer 3 Power ON the computer and run the EXCEL software Down load the saving data file for example the file name HTA01001...

Страница 18: ...d Setting mode then press the Next Button 3 3 Fig 1 once a while display will show dAtE Set clock time Year Month Date Hour Minute Second dEC Set SD card Decimal character PoFF Auto power OFF manageme...

Страница 19: ...st the value Setting start from Year value After the desired value is set press the Enter Button 3 4 Fig 1 once will going to next value adjustment for example first setting value is Year then next to...

Страница 20: ...er value to bASIC or Euro bASIC Use as the Decimal point with default Euro Use as the Decimal point with default 2 After select the upper text to bASIC or Euro press the Enter Button 3 4 Fig 1 will sa...

Страница 21: ...N 2 After select the upper text to yES or no press the Enter Button 3 4 Fig 1 will save the setting function with default 7 5 Select the Thermometer to Type K or Type J When the lower display show tYP...

Страница 22: ...7 Set sampling time SecondS When the lower display show SP t 1 Use the Button 3 6 Fig 1 or Button 3 5 Fig 1 to adjust the value 1 2 5 10 30 60 120 300 600 1800 3600 seconds 2 After teh Sampling value...

Страница 23: ...nput Socket 3 12 Fig 1 The meter will permanent power ON when use the DC ADAPTER power supply The power Button function is disable 9 BATTERY REPLACEMENT 1 When the left corner of LCD display show it i...

Страница 24: ...method During the power on use a pin to press the Reset Button 3 11 Fig 1 once a while will reset the circuit system 11 RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3 5...

Страница 25: ...0 Each digit indicates the following status D0 End Word D1 D8 Display reading D1 LSD D8 MSD For example If the display reading is 1234 then D8 to D1 is 00001234 D9 Decimal Point DP position from right...

Страница 26: ...ra fast response naked bead thermocouple suitable for many general purpose application Thermocouple Measure Range 50 to 900 Probe 58 to 1650 Type K TP 02A Dimension 12cm tube 3 2mm Dia Thermocouple Me...

Страница 27: ...ard structure already get patent or patent pending in following countries Germany Nr 20 2008 016 337 4 JAPAN 3151214 TAIWAN M 358970 M 359043 CHINA ZL 2008 2 0189918 5 ZL 2008 2 0189917 0 USA Patent p...