background image

100 Kg

SD Card real time recorder

10 ms sampling time recorder

FORCE GAUGE

Model : FG-6100SD

Your purchase of this
FORCE GAUGE marks a
step forward for you
into the field of precision
measurement.  Although
this FORCE GAUGE is a
complex and delicate
instrument, its durable
structure will allow many
years of use if proper
operating techniques are
developed. Please read
the following instructions
carefully and always keep
this manual within easy
reach.

       OPERATION MANUAL

Содержание FORCE GAUGE FG-6100SD

Страница 1: ...step forward for you into the field of precision measurement Although this FORCE GAUGE is a complex and delicate instrument its durable structure will allow many years of use if proper operating tech...

Страница 2: ...T Button 6 3 9 LOGGER SAMPLING CHECK Button 6 3 10 RS 232 output terminal 6 3 11 Reset terminal 6 3 12 DC 9V Power Adapter Input Socket 6 3 13 Mounting Holes fixing Screws 6 3 14 Battery Cover Compart...

Страница 3: ...0 second 13 5 4 Peak hold record mode Fast Datalogger 14 5 5 Check time information 15 5 6 Check sampling time information 15 5 7 SD Card Data structure 15 6 Saving data from the SD card to the comput...

Страница 4: ...ve the measuring data along the real time value Year Month Date Hour Minute Second into the SD card per normal sampling time 1 second to 8 hours After save the data into the SD memory card it can be d...

Страница 5: ...stal display 5 digits 16 mm 0 63 digit size Back light Display Positive or Reverse direction select by Direction the push button on the front panel Function Tension Compression Push Pull Normal force...

Страница 6: ...ata record Each setting step is 10 mS mode Auto data logger Sampling Time The memory circuit will store 1000 Setting range data no max measuring data Data error no 0 1 of total saved data max Memory C...

Страница 7: ...s optional Power Current Normal operation w o SD card save data and LCD Backlight is OFF Approx DC 7 mA When SD card save the data and LCD Backlight is OFF Approx DC 38 mA A If LCD backlight on the po...

Страница 8: ...2 meter cable 1 PC Carrying case 1 PC Optional T SD memory card 2 GB Accessories Test stand Model FS 1001 Electrical test stand Model FS 1002 Wedge grip Model WG 01 RS232 cable Model UPCB 02 USB cable...

Страница 9: ...3 FRONT PANEL DESCRIPTIONS Fig 1 6...

Страница 10: ...R Button 3 7 DISPLAY REVERSE Button 3 8 TIME SET Button 3 9 LOGGER SAMPLING CHECK Button 3 10 RS 232 output terminal 3 11 Reset terminal 3 12 DC 9V Power Adapter Input Socket 3 13 Mounting Holes fixin...

Страница 11: ...tion for the measurement 1 Compression measurement the display will show the mark automatically Tension Compression 2 During the measurement the SENSING HEAD along the adapter has to be on a line with...

Страница 12: ...press Power Button 3 3 Fig 1 2 seconds will power off 2 Determine display unit of Kg lb or Newton by selecting the unit at first with default refer to chapter 7 ADVANCED SETTING 3 Insert the Sensor Pl...

Страница 13: ...operation of fast sampling time measurement If the LCD show SLOW indicator the display reading is under the slow sampling time measurement Over range display of tension function LCD will show Over ran...

Страница 14: ...memory card 4 GB Prepare a SD memory card 1 GB to 16 GB optional insert the SD card into the SD card socket 3 18 Fig 1 When plug in the SD card the up side of the SD card should face against the down...

Страница 15: ...setting the Decimal point refer to Chapter 7 8 page 24 5 2 Normal record mode Auto Datalogger Set sampling time 1 second a Start the datalogger Press the LOGGER Button 3 9 Fig 1 2 seconds continuously...

Страница 16: ...the Datalogger Press the LOGGER Button 3 9 Fig 1 2 seconds continuously the DATA RECORD indicator will be disappeared and finish the Datalogger 5 3 Normal record mode Manual Datalogger Set sampling t...

Страница 17: ...1002 Power on the meter 2 Press the PEAK Button 3 6 Fig 1 once the Display will the indicator PEAK and FAST 3 Press the Zero Button 3 4 Fig 1 once the Display will set to ZERO value 4 Press the LOGGER...

Страница 18: ...LCD display will present the time information of Hour Minute Second h m s in the lower Display 2 If press Time Button 3 8 Fig 1 once again the lower LCD display will present the time information of Ye...

Страница 19: ...e to the FGC01001 XLS until Data column reach to 30 000 columns then will generate a new file for example FGC01002 XLS 3 Under the folder FGC01 if the total files more than 99 files will generate anew...

Страница 20: ...nto the SD card adapter then connect the SD card adapter into the computer 3 Power ON the computer and run the EXCEL software Down load the saving data file for example the file name FGC01001 XLS FGC0...

Страница 21: ...EXCEL data screen for example peak hold record mode EXCEL graphic screen for example graphic 1 18...

Страница 22: ...ton 3 8 Fig 1 once a while in sequence to select the eight main function the display will show Sd F SD memory card Format dAtE Set clock time Year Month Date Hour Minute Second SP t Set sampling time...

Страница 23: ...gain the Display will show text yES Enter to confirm again if make sure to do the SD memory card format then press Enter Button once will format the SD memory clear all the existing data that already...

Страница 24: ...When the upper display show SP t 1 Use the Button 3 4 Fig 1 or Button 3 7 Fig 1 to adjust the value Setting start from Hour value After the desired value is set press the Enter Button 3 6 Fig 1 once w...

Страница 25: ...usted value range is from 10 ms to 500 ms 2 After set the sampling time value press the SET Button 3 6 Fig 1 once the screen will jump to Auto power OFF setting screen Chapter 7 5 7 5 Auto power OFF m...

Страница 26: ...ll save the setting function with default 7 7 Set the measurement unit When the lower display show unit 1 Use the Button 3 4 Fig 1 or Button 3 7 Fig 1 to select the measurement unit in Kg lb N in the...

Страница 27: ...elect the upper text to bASIC or Euro USA Use as the Decimal point with default Euro Use as the Decimal point with default 2 After select the upper text to USA or Euro press the Enter Button 3 6 Fig 1...

Страница 28: ...y indicator appears before the instrument become inaccurate 2 Loose the screws of the Battery Cover 3 14 Fig 1 and take away the Battery Cover from the instrument and remove the battery 3 Replace with...

Страница 29: ...nection will be required to link the instrument with the PC serial port Meter PC 9W D Connector Center Pin Pin 4 3 5 mm jack plug Ground shield Pin 2 2 2 K resister Pin 5 The 16 digits data stream wil...

Страница 30: ...it 1 Stop bit 12 MOUNTING HOLES OPTIONAL TEST STAND FORCE GAUGE is a precise instrument best results are obtained when the gauge is fitted to a test stand Mounting holes 3 13 Fig 1 are provided on the...

Страница 31: ...1 Electronics Test strength of solder points and spot welds on circuit boards Test wire wraps on clip connection Test pull strength of modified wire wrap connection on posts Test spring clip insertio...

Страница 32: ...ments on push buttons and flip switches 13 3 Chemical Plastics Test film bond strengths Tensile test rubber fibers and filaments Measure firmness of polyurethane foam Test crush strength of pills medi...

Страница 33: ...hood glove compartment brake pedal etc 13 6 Other Industries Measure pedal depression force in aircraft Test hardness of gypsum wallboard Test keyboard and pedal contact force of organs and pianos Te...

Отзывы: