Status LED Bar Blink Codes
Blink Pattern
Indication
5-second blink • No network cable connection.
Rotating
• Bridge firmware is updating if the status
LEDs are progressing around the bridge
in sequence.
• Firmware is updating. The Lutron
Connect
TM
bridge is not functional during
a firmware update.
Please Read Before Installing
Use these instructions to install the model numbers
listed above.
For more information visit: www.lutron.com/radiora2
or www.lutron.com/hwqs
Features
•
Add button
allows the bridge to be activated in a
RadioRA
®
2 or HomeWorks
®
QS system and the
Lutron Connect
TM
Mobile App.
•
Ethernet port
allows the bridge to be connected to a
wireless router.
Important Notes
Environment
Ambient operating temperature: 32 °F to 104 °F
(0 °C to 40 °C), 0% to 90% humidity. Indoor use only.
Codes
Install in accordance with all local and national
electrical codes.
Cleaning
To clean, wipe with a clean damp cloth. DO NOT use
any chemical cleaning solutions.
DC Power Adapter
Using a DC power adapter not rated at the proper
specifications could damage the Lutron Connect
TM
bridge
and possibly overheat the DC power adapter. Ensure that
the DC power adapter follows the proper specifications
as detailed above.
Programming
Programming and activation (addressing) must be
accomplished through the RadioRA
®
2 or
HomeWorks
®
QS software.
Lutron Elec tron ics Co., Inc.
7200 Suter Road Coopersburg, PA 18036-1299
Returning Lutron Connect
TM
Bridge to
Factory Settings
Returning the Lutron Connect
TM
bridge to its factory
settings will erase all its programming and will require
the Lutron Connect
TM
bridge to be reactivated into the
system.
1. Triple tap and hold the “Add” button. DO NOT release
the button after the third tap.
2. Keep the button pressed on the third tap until the
LEDs start to flash.
3. Release the button and immediately triple tap it again.
The LEDs will flash quickly. When the LEDs stop
flashing, the Lutron Connect
TM
bridge has been
returned to its factory settings.
Lutron, HomeWorks, and RadioRA are registered trademarks and RadioRA 2 and Lutron Connect are trademarks of Lutron Electronics Co., Inc.
NEC is a registered trademark of National Fire Protection Association, Quincy, Massachusetts. © 2016 Lutron Electronics Co., Inc.
English
CONNECT-BDG-1
CONNECT-BDG-2
Installation Instructions
* Typical Power Consumption test conditions: LED on, Ethernet cable
plugged in, powered by the 5 V
-
adapter.
041531b
02/2016
Installation
1. Using the Ethernet cable, connect the Lutron Connect
TM
bridge to a wireless router on the same network (subnet)
as the RadioRA
®
2 main repeater or the HomeWorks
®
QS
processor.
2. Attach the DC power adapter cord to the power jack on
the Lutron Connect
TM
bridge and insert the DC power
adapter plug into a receptacle.
3. Use the RadioRA
®
2 or HomeWorks
®
QS design software
to activate the Lutron Connect
TM
bridge into the system.
Ensure convenient access to the “Add” button because it
will be used for activating the bridge into the system and
pairing with the Lutron Connect
TM
App.
4. Use the Lutron Connect
TM
App to control and monitor the
system through the Lutron Connect
TM
bridge. The “Add”
button will be used for pairing the app to the bridge.
Dimensions
Measurements shown as: in (mm)
Front View
1.19
(30.2)
2.75
(69.9)
Top View
2.75
(69.9)
2.75
(69.9)
Connections
Back View
“Add” Button
Power Jack (to adapter)
NEC
®
Class 2, LPS or SELV, limited energy (<15 W)
Ethernet CAT5 Port
Lutron Connect
TM
Bridge
DC Power Adapter
Ethernet
Cable
CONNECT-BDG-1
(5 V
-
300 mA)
T-5DC-USB-WH
(included):
Input
: 100 – 240 V
~
50/60 Hz 100 mA;
Output
: 5 V
-
550 mA
Included
CONNECT-BDG-2
(5 V
-
300 mA)
Not included. Use LPS or SELV output
5 V
-
550–1000 mA USB Micro
Connector
Included
Typical Power Consumption*: 1.3 W
Warranty
For warranty information, please see the Warranty
enclosed with the product, or visit
www.lutron.com/resiinfo
FCC/IC Information
For FCC/IC information, please visit
www.lutron.com/fcc-ic
Customer Assistance
Online:
forums.lutron.com | www.lutron.com/help
Email:
Phone:
U.S.A./Canada:
1.844.LUTRON1 (588.7661)
Europe:
+44.(0)20.7680.4481
Mexico:
+1.888.235.2910
Other Countries:
+1.610.282.3800
Setup
Wired
RF
Communication
Repeater Status
1
3
4
2
M
Power Repeater Link
COM
9 V
1
N / C
MUX
MUX
2
3
4
Add
Test
USB
Integrate
Program / Integrate
RS232
Ethernet
Main Repeater
HomeWorks
®
QS Processor
Lutron Connect
TM
Bridge
Lutron
Connect
TM
App
HomeWorks
®
QS Processor
Wireless Router
(not sold by Lutron)
Ethernet
Connection
Ethernet
Connection
DC Power
Adapter
24 V
-
Input
Setup
Wired
RF
Communication
Repeater Status
1
3
4
2
M
Power Repeater Link
COM
9 V
1
N / C
MUX
MUX
2
3
4
Add
Test
USB
Integrate
Program / Integrate
RS232
Ethernet
Main Repeater
RadioRA
®
2 Main Repeater
Lutron Connect
TM
Bridge
Lutron
Connect
TM
App
RadioRA
®
2 Main Repeater
Wireless Router
(not sold by Lutron)
Ethernet
Connection
Ethernet
Connection
DC Power
Adapter
Status LED Bar
Lutron Connect
TM
Bridge