Status LED Bar Blink Codes

Blink Pattern

Indication

5-second blink • No network cable connection.
Rotating

•  Bridge firmware is updating if the status 

LEDs are progressing around the bridge 

in sequence.

•  Firmware is updating. The Lutron 

Connect

TM

 bridge is not functional during 

a firmware update.

Please Read Before Installing

Use these instructions to install the model numbers 

listed above.  

For more information visit: www.lutron.com/radiora2  

or www.lutron.com/hwqs

Features

• 

Add button

 allows the bridge to be activated in a 

RadioRA

®

 2 or HomeWorks

®

 QS system and the 

Lutron Connect

TM

 Mobile App.

• 

Ethernet port

 allows the bridge to be connected to a 

wireless router.

Important Notes

Environment

Ambient operating temperature: 32 °F to 104 °F  

(0 °C to 40 °C), 0% to 90% humidity. Indoor use only.

Codes

Install in accordance with all local and national 

electrical codes.

Cleaning

To clean, wipe with a clean damp cloth. DO NOT use 

any chemical cleaning solutions.

DC Power Adapter

Using a DC power adapter not rated at the proper 

specifications could damage the Lutron Connect

TM

 bridge 

and possibly overheat the DC power adapter. Ensure that 

the DC power adapter follows the proper specifications 

as detailed above. 

Programming

Programming and activation (addressing) must be 

accomplished through the RadioRA

®

 2 or 

HomeWorks

®

 QS software.

Lutron Elec tron ics Co., Inc.

7200 Suter Road  Coopersburg, PA 18036-1299

Returning Lutron Connect

TM

 Bridge to 

Factory Settings

Returning the Lutron Connect

TM

 bridge to its factory 

settings will erase all its programming and will require 

the Lutron Connect

TM

 bridge to be reactivated into the 

system.

1. Triple tap and hold the “Add” button. DO NOT release 

the button after the third tap.

2. Keep the button pressed on the third tap until the 

LEDs start to flash.

3. Release the button and immediately triple tap it again. 

The LEDs will flash quickly. When the LEDs stop 

flashing, the Lutron Connect

TM

 bridge has been 

returned to its factory settings.

Lutron, HomeWorks, and RadioRA are registered trademarks and RadioRA 2 and Lutron Connect are trademarks of Lutron Electronics Co., Inc.

NEC is a registered trademark of National Fire Protection Association, Quincy, Massachusetts. © 2016 Lutron Electronics Co., Inc.

English

CONNECT-BDG-1
CONNECT-BDG-2

Installation Instructions

*  Typical Power Consumption test conditions: LED on, Ethernet cable 

plugged in, powered by the 5 V

-

 adapter.

041531b

02/2016

Installation

1. Using the Ethernet cable, connect the Lutron Connect

TM

 

bridge to a wireless router on the same network (subnet) 

as the RadioRA

®

 2 main repeater or the HomeWorks

®

 QS 

processor.

2. Attach the DC power adapter cord to the power jack on 

the Lutron Connect

TM

 bridge and insert the DC power 

adapter plug into a receptacle.

3. Use the RadioRA

®

 2 or HomeWorks

®

 QS design software 

to activate the Lutron Connect

TM

 bridge into the system. 

Ensure convenient access to the “Add” button because it 

will be used for activating the bridge into the system and 

pairing with the Lutron Connect

TM

 App.

4. Use the Lutron Connect

TM

 App to control and monitor the 

system through the Lutron Connect

TM

 bridge. The “Add” 

button will be used for pairing the app to the bridge.

Dimensions

Measurements shown as: in (mm)

Front View

1.19

(30.2)

2.75

(69.9)

Top View

2.75

(69.9)

2.75

(69.9)

Connections

Back View

“Add” Button

Power Jack (to adapter)

NEC

®

 Class 2, LPS or SELV, limited energy (<15 W)

Ethernet CAT5 Port

Lutron Connect

TM

 

Bridge

DC Power Adapter

Ethernet 

Cable

CONNECT-BDG-1 

(5 V

-

  300 mA)

T-5DC-USB-WH

 (included): 

Input

:  100 – 240  V

~

  50/60 Hz  100 mA;  

Output

: 5 V

-

  550 mA

Included

CONNECT-BDG-2 

(5 V

-

  300 mA)

Not included. Use LPS or SELV output 

5 V

-

  550–1000 mA USB Micro 

Connector

Included

Typical Power Consumption*: 1.3 W

Warranty

For warranty information, please see the Warranty 

enclosed with the product, or visit  

www.lutron.com/resiinfo

FCC/IC Information

For FCC/IC information, please visit  

www.lutron.com/fcc-ic

Customer Assistance

Online:

 forums.lutron.com | www.lutron.com/help

Email:

 [email protected]

Phone: 

U.S.A./Canada:

 1.844.LUTRON1 (588.7661)

Europe:

 +44.(0)20.7680.4481

Mexico:

 +1.888.235.2910

Other Countries: 

+1.610.282.3800

Setup

Wired

RF

Communication

Repeater Status

1

4

2

 

M

Power Repeater Link

COM

9 V

1

N / C

MUX

MUX

2

3

4

Add

Test

USB

Integrate

Program / Integrate

RS232

Ethernet

Main Repeater

HomeWorks

®

 QS Processor

Lutron Connect

TM

 Bridge 

Lutron 

Connect

TM

 

App

HomeWorks

®

 

QS Processor

Wireless Router 

(not sold by Lutron)

Ethernet 

Connection

Ethernet 

Connection

DC Power 

Adapter

24 V

-

  

Input

Setup

Wired

RF

Communication

Repeater Status

1

4

2

 

M

Power Repeater Link

COM

9 V

1

N / C

MUX

MUX

2

3

4

Add

Test

USB

Integrate

Program / Integrate

RS232

Ethernet

Main Repeater

RadioRA

®

 2 Main Repeater

Lutron Connect

TM

 Bridge 

Lutron 

Connect

TM

 

App

RadioRA

®

 2 Main Repeater

Wireless Router 

(not sold by Lutron)

Ethernet 

Connection

Ethernet 

Connection

DC Power 

Adapter

Status LED Bar

Lutron Connect

TM

 Bridge

Отзывы: