Error
Cause
Remedy
ATT1
Parameter cannot be changed at current
user level or is not editable.
Select user level 1-MODE higher.
ATT2
Motor must not be controlled via the CTRL
menu.
Cancel start signal from a
different control location.
ATT3
Motor must not be controlled via the CTRL
menu because of error state.
Reset error.
ATT4
New parameter value impermissible
Change value.
ATT5
New parameter value too high
Reduce value.
ATT6
New parameter value too low
Increase value.
ATT7
Card must not be read in current state.
Reset start signal.
ERROR
Invalid password
Enter correct password.
Table 5.2
KeyPad
USER
ERROR
: Reset with
start/enter
Error
Meaning
Remedy
ERR91
S
MART
C
ARD
write-protected
Use different
S
MART
C
ARD
ERR92
Error in plausibility check
ERR93
S
MART
C
ARD
not readable, wrong CDD3000-HF type
ERR94
S
MART
C
ARD
not readable, parameter not compatible
ERR96
Connection to S
MART
C
ARD
broken
ERR97
S
MART
C
ARD
DATA
invalid (checksum)
ERR98
Insufficient memory on S
MART
C
ARD
ERR99
Selected area not present on S
MART
C
ARD
, no parameters
transferred to S
MART
C
ARD
Table 5.3
S
MART
C
ARD
error: Reset with
stop/return
Error
Cause
Remedy
Power on. CDD3000-HF
shows no response (LEDs
off).
If switching is too frequent,
the device protects itself by
means of high-resistance
isolation from the system.
After a rest phase of a few
minutes the device is ready
to start once again.