CDD3000-HF Operation Manual
3-3
3 Installation
DE
EN
FR
IT
ES
FR
1) For supplementary components see Order Catalogue for highspeed drive systems.
2) In CDD3000-HF drive controllers up to 11.8 kVA (BG1 to BG4) the mains filter is built-in.
For all shielded
connections a cable
type with double
copper braiding with
60-70% coverage must
be used.
Key
Explanation
(1)
Line choke
1)
Reduces the voltage distortions in the system
(2)
Mains filter
1) 2)
Suppresses line-borne interference emission
(3)
Braking resistor
1)
Required for fast braking
(4)
Control connections X2
Connection, see section 3.6
(5)
Motor PTC connection X3
For thermal monitoring of the motor,
see section 3.3.2
(6)
RS232 connection X4
For operation with K
EY
P
AD
/D
RIVE
M
ANAGER
,
(8)
Software name plate
Indicates the shipped software status
(9)
Name plate
Contains the hardware data and the serial number
(10) Encoder simulation/master
encoder X5, TTL encoder
Connection and specification, see section 3.8
(11) Resolver connection X6
Connection and specification, see section 3.3.3
(12) opt. Encoder connection X7 Connection and specification, see section
(13) motor filter
1)
Reduces harmonic current waves