3-4
Engineering Guide CDA3000
3 Selection of inverter module
Three-phase inverter modules
Inverter module
Rec. 4-pole
standard motor
Rated current
Peak current
Power loss
at 4 kHz
Device output
CDA34.003,Cx.x
0.75 kW
2,2 A
4.0 A
1)
45 W
1.5 kVA
CDA34.005,Cx.x
1.5 kW
4.1 A
7.4 A
1)
80 W
2.8 kVA
CDA34.006,Cx.x
2.2 kW
5.7 A
10.3 A
1)
100 W
3.9 kVA
CDA34.008,Wx.x
3.0 kW
7.8 A
14 A
1)
140 W
5.4 kVA
CDA34.010,Wx.x
4.0 kW
10 A
18 A
1)
180 W
6.9 kVA
CDA34.014,Wx.x
5.5 kW
14 A
25 A
1)
210 W
9.7 kVA
CDA34.017,Wx.x
7.5 kW
17 A
31 A
1)
270 W
11.7 kVA
CDA34.024,Wx.x
11 kW
24 A
43 A
1)
390 W
16.6 kVA
CDA34.032,Wx.x
15 kW
32 A
58 A
1)
480 W
22.1 kVA
CDA34.045,Wx.x
22 kW
45 A
81 A
2)
600 W
31 kVA
CDA34.060,Wx.x
30 kW
60 A
90 A
2)
720 W
42 kVA
CDA34.072,Wx.x
37 kW
72 A
108 A
2)
840 W
52 kVA
CDA34.090,Wx.x
45 kW
90 A
135 A
2)
1080 W
62 kVA
CDA34.110,Wx.x
55 kW
110 A
165 A
2)
1300 W
80 kVA
CDA34.143,Wx.x
75 kW
143 A
214 A
2)
1680 W
104 kVA
CDA34.170,Wx.x
90 kW
170 A
255 A
2)
2040 W
125 kVA
1) 1.8 x I
N
for 30 s
2) 1.5 x I
N
for 60s
Mains voltage 3 x 460 V -25 % +10 %
Mains frequency 50/60 Hz ±10 %
Cooling air temperature
(1000 m above MSL) 45 °C at 4 kHz
Power stage switching frequency 4,
8
, 16 kHz
Output frequency 0 ... 1600 Hz to 15 kW
0 ... 400 Hz 22 kW to 90 kW
Table 3.2
Overview of inverter modules for 460 V systems
Содержание CDA3000
Страница 62: ...Engineering Guide CDA3000 2 29 2 Drive definition DE EN 1 2 3 4 5 6 7 A Notes ...
Страница 315: ...A 24 Engineering Guide CDA3000 Appendix A Formula bank Movement by rack Movement by cable reel Movement by spindle ...
Страница 317: ...A 26 Engineering Guide CDA3000 Appendix A Formula bank Indexing table with eccentric loads ...
Страница 336: ...Engineering Guide CDA3000 A 45 DE EN FR 1 2 3 4 5 6 A Appendix B Practical working aids for the project engineer ...