Engineering Guide CDA3000
5-3
5 Communication and user modules
DE
EN
1
2
3
4
5
6
7
A
5.2
User module
With the user module UM-8I40 the digital inputs and outputs of the
inverter module are expanded by eight inputs and four outputs. The
functionality of the expanded inputs and outputs corresponds to that of
the I/Os of the inverter module.
Figure 5.2
UM 8I4O
Technical data
UM-8I4O
Voltage supply
24 VDC ±20 %
Current consumption
0.6 A
Eight inputs
Input voltage for signal “0”
from 0 to 5 V
Input voltage for signal “1”
>15 V
Input current with signal “1”
3.5 mA to 7.0 mA
(6 mA at 24 VDC)
Four outputs
Output current
Permissible
range with
signal “1”
min. 5 mA max. 0.5 A
Mean
125 mA
Total current
0.5 A
Short-circuit cur-
rent per output
max. 1.2 A short-time
Dimensions
(W x H x D)
28 x 90 x 90 [mm]
Table 5.1
Technical data
Содержание CDA3000
Страница 62: ...Engineering Guide CDA3000 2 29 2 Drive definition DE EN 1 2 3 4 5 6 7 A Notes ...
Страница 315: ...A 24 Engineering Guide CDA3000 Appendix A Formula bank Movement by rack Movement by cable reel Movement by spindle ...
Страница 317: ...A 26 Engineering Guide CDA3000 Appendix A Formula bank Indexing table with eccentric loads ...
Страница 336: ...Engineering Guide CDA3000 A 45 DE EN FR 1 2 3 4 5 6 A Appendix B Practical working aids for the project engineer ...