4-42
Engineering Guide CDA3000
4 Software functions
(ASTER=ROT_1)
Rotational drive (configuration 6)
Figure 4.30
Control terminal assignment with ASTER=ROT_1
Function
Application
•
Analog speed input for two directions
of rotation
•
Adjustment of speed via button (MOP
function)
•
Spindle
•
Winding drive
•
Vacuum pumps
•
Extruder
•
Stirrer
•
etc.
X2
Function
1
Reference voltage 10 V, 10 mA
2
Reference -10 V ... + 10 V
3
not assigned
4
Actual frequency
0 ... 10V corr. to 0 ... FMAX
5
6
Auxiliary voltage 24V max.
200 mA
7
8
Power stage hardware enable
9
Start/Stop clockwise
10
Start/Stop anti-clockwise
11
Increase speed
12
Reduce speed
13
Auxiliary voltage 24 V
14
Digital ground
15
Message: “References
reached”
16
Standstill
17
Digital ground
18
Relay contact (break)
19
Relay contact (make)
for "ready" signal
20
X3
Function
1
Motor PTC evaluation
Function inactive
2
K0
H2
H1
R1
N1
S2
ENPO
STR
STL
S1