3-44
Engineering Guide CDA3000
3 Selection of inverter module
Current characteristic, CDA34.003,Cxx (0.75 kW)
Cooling method:
Cold plate without additional cooling area
Motor cable length:
10 m
Rated current:
2.2 A
Switching frequency
of power stage:
4, 8, 16 kHz
Mains voltage:
3 x 460 V
Mounting type:
side-by-side
Mounting height:
1000 m
Figure 3.15
Max. current load of the CDA34.003,Cx.x / 0.75 kW / side-by-
side / without additional cooling area / mains voltage 3 x 460 V
20
25
30
35
40
45
50
55
0.5
1
1.5
2
2.5
I
[A]
~ ~
[˚C] Cooling air temperature
J
K
16 kHz
8 kHz
4 kHz
2.2 A
2.2 A
1.25 A
1 A
1.8 A