141
ENGLISH
Motion detection:
An alarm is transmitted only, if the PIR and the microwave sensor detect a motion.
With the range button set to maximum, the detection range is about 15 metres, if
the motion detector is installed at a height of 1.9 to 2.0 metres (vertical to the wall).
With the range button set to minimum, the detection range is about 3 to 5 metres,
if the motion detector is installed at a height of 1.9 to 2.0 metres (vertical to the
wall).
Test mode:
You can set the PIR/microwave motion detector in the test mode by pressing the
Learn/test button for a few seconds. The standby mode is disabled while the test
mode runs. The respective LED will light up with every motion detected.
Microwave test mode:
To adjust the optimal sensitivity/range of the microwave sensor, you can start the test
mode for the microwave detection only. For that purpose, set Jumper 3 (JP3) to ON.
With the microwave test mode enabled, the microwave LED lights up for 0.5 seconds
upon every motion detected. Any further detection extends the duration by 0.5
seconds.
Battery:
The PIR/microwave motion detector requires a CR123A Lithium battery 3 V.
With the Supervisor Jumper (JP2) set to OFF, the battery status is transmitted
according to the control unit settings.
Note:
If it is required to change the battery, please note that tamper alarm may be triggered
(depending on the control unit settings). Remove the empty battery. Press the Learn
button twice to make sure that the remaining power is discharged. Then insert the
new battery.
Put the PIR / microwave motion detector into operation
1.
Open the detector and insert the provided battery.
2.
The device starts. This process takes about 30 seconds. Wait until the LEDs
stopped flashing and avoid triggering the detector during that time!
3.
Open the configuration menu of the control unit and then the sub-menu Sensors
Add. Click on Start.
4.
Press the Test/learn button of the detector once. The menu should list the
PIR/microwave motion detector after a short while. Click on Add to complete the
learn process.
5.
Start the test mode of the control unit to check whether the motion detector at the
intended location is within the range.
6.
For that purpose, take the motion detector to the intended place of installation and
press the Test button of the motion detector. The menu of the control unit indicates
the signal strength. The higher the indicated number the better the reception (1-9).