CO detector
Product description:
1.
Two colour LED
Flashes yellow: low battery
2 x red + 2 beeps: transmission
Flashes red: Alarm
2.
Test button
Activates the test and range mode
Deactivate alarm
Note:
The LUPUSEC CO detector reports exclusively the escape of carbon monoxide.
We recommend installing the CO detector at a height of approx. 1.5 metres, as
carbon monoxide weighs about as much as air and is evenly distributed in the
room.
Battery:
The CO detector requires three AA batteries 1.5 V. The average battery life is two
years. The CO detector will inform the control unit, if the battery is running low about
two months before they are empty.
Put the CO detector into operation:
To put the CO detector into operation, proceed as follows:
1.
Insert the supplied batteries.
2.
After their insertion, the CO detector emits two short beeps and the LED lights up
once in red.
3.
Close the housing.
4.
Open the configuration page of the control unit, open the menu “Sensors”
“Add”
and click on Start.
5.
Press the test button of the CO detector for about one second.
6.
The configuration page of the control unit should list the CO detector.
7.
Add the CO detector.
8.
You can test the signal strength in the Range menu. For that purpose, go to the
intended place of installation, press Range test
Start in the control unit menu
Sensors
Range and then press the Test button of the CO detector. The higher
the indicated number the better the reception (1-9).