Factory:

No.14, Jalan Anggerik Mokara 31/44, Kota Kemuning Seksyen 31,

40460 Shah Alam, Selangor, Malaysia. 

Tel: (00603) 5121 1887

Fax: (00603) 5121 5187

Email: [email protected]

o

o

o

o

o

o

o

Housing made of die-cast aluminium

Impact resistance tempered glass cover

Stainless steel screws

Operating temperature: -20°C~+40°C.

LED lifetime up to 50,000 hours

Voltage range: 100 - 277 VAC ~ 50 /60 Hz

Wattage: 40 W & 52 W

PRODUCT DESCRIPTION & DIMENSION

IP 65  IK 08 CLASS I WITH INTERGRAL DRIVER

WARNING

!

MAKE SURE POWER IS DISCONNECTED UNTIL INSTALLATION OF PRODUCT IS COMPLETELY FINISHED.

FAILURE TO DO SO COULD RESULT IN ELECTRICAL SHOCK CAUSING SERIOUS INJURY OR DEATH.

PTL-14A-J-W40-30-xx

PTL-14A-J-W40-40-xx

DESCRIPTION

MODEL:

Connect wires from the luminaire to AC power as follows:

1.  Connect BLUE / BLACK wire to the NEUTRAL wire.

2.  Connect GREEN / YELLOW-GREEN wire to the GROUND or EARTH wire.

3.  Connect BROWN / RED wire to the LIVE wire.

POLE INSTALLATION

!

WIRING INSTALLATION

Singapore Office (HQ Sales & Marketing):

1 Coleman Street #10-06, The Adelphi, 

179803, Singapore.

Tel: (0065) 9758 2771

[email protected] 

www.lumzlighting.com 

PT 1011/INSTALLATION MANUAL/REV.0

1/2

Connect all wires from the luminaire to AC power using a connector. 

Make sure all wiring connections are tight so that no bare wires are visible.

Good connections may avoid tripping from happening.

BASE PLATE DIMENSION

# Make sure power is 

disconnected before 

installation

Fix pole to ground by 

placing base plate over 

the concrete and let all 

bolts pass through base 

plate holes.

Insert and tighten 

washers & nuts.

SERVICE DOOR INSTALLATION

Place fuse plate inside 

the pole and fix it with 

screws provided.

Place service door on 

surface of pole and fix it 

with screws provided. 

PTL-15A-J-W55-30-xx

PTL-15A-J-W55-40-xx

PTL-15B-J-W40-30-xx

PTL-15B-J-W40-40-xx

# Pole sold separately

Pole is available upon request, please consult us for more details. 