background image

AC Triton

White:  Neutral

Black:    Line

Green:   Safety Ground

The ground (green) conductor is not internally connected to either the neutral (white) or line (black) conductors.  The 

ground conductor must be connected to a suitable safety ground in compliance with applicable electrical codes.  The 

electrical supply must be externally protected by a fuse or circuit breaker suitable for the intended operating current.   

    

DC Triton

White:  + 12 or + 24 VDC (Positive)

Black:   -12 or -24 VDC (Negative)

The positive (white) and negative (black) conductors are electrically isolated from the Triton housing.  Due to the high 

power of these lights extra attention should be paid to the selection of the wire size.  A maximum voltage drop of 1 volt is 

recommended.  (As an example,  a 12 volt light located 20 feet from the power source would require #12 AWG wire – 

consult the ABYC voltage drop table or other reference for the correct distance / wire gauge combinations).     The 

electrical supply must be externally protected by a fuse or circuit breaker suitable for the intended operating current and 

wire gauge.

Light Head Assembly

The Triton Light Head Assembly is designed for OEM use. This light requires an area of 14” x 5 ½” for mounting. Make sure 

adequate space is available on the mounting surface before drilling holes. (see back) Drill a ½” through hole in the center 

of the mounting position for the power wires to pass. This light arrives with 4 temporary plastic wings nuts on each of the 

4 corner bolts. Remove the wing nuts and use the 4 remaining 10-24 machine screws with your choice of nuts. Or, replace 

the 4 corner bolts with your choice of #10 tapping screw. (Stainless Steel hardware is recommended)

Pole Mount/Bracket Mount

Pole Mount - This light comes equipped with a ¾” NPT flange for easy adapting to many standard configurations. 

Bracket Mount - This light comes equipped with a rotational mounting bracket intended for mounting to flat surfaces. 

Mounting hardware can be substituted but it is recomended that Stainless Steel hardware be used regardless of fastener 

type.

Surface Mount

This light requires an area of 14” x 5 ½” for mounting. Make sure adequate space is available on the mounting surface 

before drilling holes. (see back) Drill a ½” through hole in the center of the mounting position for the power wires to pass. 

This light arrives with 4 temporary plastic wings nuts on each of the 4 corner bolts. Remove the wing nuts and use the 4 

remaining 10-24 machine screws with your choice of nuts. Or, replace the 4 corner bolts with your choice of #10 tapping 

screw. (Stainless Steel hardware is recommended)Apply a small ring of Silicone RTV around the wire exit hole on the rear 

of the surface mount plate to ensure proper sealing.Make sure when the light is mounted that the Triton badge reads 

normally. (not upside down) This will ensure proper airflow for cooling.

Semi-Recess Mount 

This light requires an area of 17 ½” x 9 ½” for mounting and requires a hole 15 ¼” wide by 7 ¼” tall by 1 ½” deep to be cut 

into the mounting surface. (see back) Make sure adequate space is available on the mounting surface before drilling holes. 

After the recess hole is cut, place and use the light assembly to mark the centers of each mounting screw position. Pre-Drill 

holes appropriately sized for the mounting surface substrate to accommodate the #10 self-tapping screws.  Apply a bead 

of Silicone RTV around the entire rear flange of the recess mount and around mounting screw holes to ensure proper 

sealing. Connect the power wires, position, and use the 8 - #10 screws provided to securely mount the fixture in place. 

Make sure when the light is mounted that the Triton badge reads normally. (not upside down) This will ensure proper 

airflow for cooling.

Limited Warranty

The product is warranted to be free from defects in workmanship and materials for a period of one year from the date of 

original purchase. Lumitec is not responsible for product failure caused by abuse, neglect, improper installation, or failure 

in applications other than those for which it was designed, intended, and marketed. Should your Lumitec product prove 

defective during the warranty period, promptly notify Lumitec and return product with freight prepaid.  Lumitec will, at its 

option, repair or replace the product or defective portion without charge for parts or labor, or, at Lumitec’s option, refund 

purchase price.  Products repaired or replaced under this warranty shall be warranted for the unexpired portion of the 

warranty applying to the original product(s).  No warranty or affirmation of fact, express or implied, other than as set forth 

in the limited warranty statement above is made or authorized by Lumitec, Inc.  Any liability for consequential and 

incidental damages is expressly disclaimed.  Lumitec liability in all events is limited to, and shall not exceed, the purchase 

price paid.

Lumitec, Inc. - 1405 Poinsettia Drive, Suite 10 - Delray Beach, FL  33444 - lumiteclighting.com

part # 600606

Pole Mount/Bracket Mount

Light Head Assembly

Surface Mount

Semi-Recess Mount

8x

Mounting 

Hardware

Mounting 

Hardware

Mounting 

Hardware

12Volt DC Triton

Voltage is 12VDC ONLY

Current is 13.2A @12VDC

24 Volt DC Triton

Voltage is 24DC ONLY

Current is 6.6A @ 24VDC

AC Triton

Input voltage range is 115 to 277 VAC, 50-60 Hz

Input current is 1.4 amps @ 115 VAC,  0.6 amps @ 277 VAC 

All Versions

Correlated Color Temperature: 5000

Color Rendering Index: 75

AC Triton

 

White:  Neutral

Black:    Line

Green:   Safety Ground

 

The ground (green) conductor is not internally connected to either the neutral (white) or line (black) 

conductors.  The ground conductor must be connected to a suitable safety ground in compliance with 

applicable electrical codes.  The electrical supply must be externally protected by a fuse or circuit 

breaker suitable for the intended operating current.  

DC Triton

 

White:  + 12 or + 24 VDC (Positive)

Black:   -12 or -24 VDC (Negative)

 

The positive (white) and negative (black) conductors are electrically isolated from the Triton housing.  

Due to the high power of these lights extra attention should be paid to the selection of the wire size.  A 

maximum voltage drop of 1 volt is recommended.  (As an example,  a 12 volt light located 20 feet from 

the power source would require #12 AWG wire – consult the ABYC voltage drop table or other refer-

ence for the correct distance / wire gauge combinations).     The electrical supply must be externally 

protected by a fuse or circuit breaker suitable for the intended operating current and wire gauge.

Отзывы: