38
Condition 1: Unit is currently running
Condition 2: Profile stored in slot 1 needs to be locked through the utility menu (see “Default Profile” on page 17)
Hold the reset button at the rear of the unit for at least five seconds to see the four status’ LED blinking
green
. If you
release the button while the status’ LED are blinking
green
, the unit will reload the profile stored in slot 1.
If you wait an addtional 5 seconds, the status’ LEDs will blink
red
, to provide you with a reset.
Releasing the reset button while the LEDs are blinking
red
will reset the unit.
Be aware that releasing the reset button during the first 5seconds before LEDS blink
green
will cancel operation.
Be aware that releasing the reset button during the 5seconds after LEDS blink
red
will cancel operation.
Hold the
reset button
Release the button =
Reload default
Release the button =
Reset
5s
Timing
Function
5s
5s
GREEN Blink
RED Blink
Condition 1: Unit is off
Hold the reset button while connecting the unit to mains. After few seconds, the four status’ LEDs will start blinking
red
.
Releasing the reset button while the LEDs are blinking red will factory reset the unit.
Be aware that releasing the reset button before LEDs blink red will cancel operation.
Be aware that releasing the reset button after LEDs blink red will cancel operation.
Hold the reset button
while powering the unit
Release the button =
Factory Reset
Release the button =
Cancel
Timing
Function
5s
18s
RED Blink
Reload Default
Factory Reset